Masterflex Gas Mass Flowmeter Controller; 0 to 50 sccm, N2/Air

为您推荐
详细介绍
Integrated valve allows precise flow control
  • Accepts a 0 to 5 VDC input signal for remote valve control
  • Calibrated for air and nitrogen
  • Maximum flow rate of 0.05 LPM

规格与描述

  • 重复性±0.5% full-scale
  • 准确性±1.5% full-scale
  • 最高压力 (psi)150
  • 最小流速 (LPM)0
  • 最大流速 (LPM)0.05
  • 最大流速 (mL/min)50
  • 材料Acetal;Viton;Anodized Aluminum
  • 触液材料Anodized Aluminum, 316 Stainless Steel, Viton, Acetal
  • ZD工作温度 (° F)50
  • ZD工作温度 (° C)10
  • 最高工作温度 (° F)122
  • 最高工作温度 (° C)50
  • 工艺连接件1/8" Compression
  • 最大流量条件下压降 (PSID)15
  • 漏气率1 X 10-4 sccs He (max)
  • 气体类型Air, Nitrogen
  • Media TypeNitrogen;Air
  • 最大粒径 (µm)20
  • 响应时间 (ms)2000
  • 输出Linear 0 to 5 VDC (2500 Ω minimum load)
  • 显示类型None
  • 已认证No
  • 描述Gas Mass Flow Controller, 0 to 50 sccm, N2/Air

包括

Two acetal compression fittings and a 24" cable with hub connector.

主要特点

  • Accepts a 0 to 5 VDC input signal for remote valve control
  • Calibrated for air and nitrogen
  • Maximum flow rate of 0.05 LPM

关于该商品的更多信息

These low-cost mass flowmeter controllers use a thermal gas flow sensing technique that results in highly accurate readings and repeatability. The controllers accept a 0 to 5 VDC input signal for remote valve control. Controllers with LCD display feature a potentiometer for manual valve control. The 3 1/2"-digit display tilts up to 90° for easy viewing. Front panel dip switch lets you select one of the factory programmed gases: air or nitrogen.
All controllers require a combined power supply/input/output cable. This cable combines three functions into one unit: power source, plus input or output of 0 to 5 VDC signals. Use the input signal for remote valve control; use the output signal for datalogging or controlling other instruments. Order the power supply/input/output cable separately.
Wetted materials are anodized aluminum, 316 stainless steel, brass, Viton®, and acetal. Maximum pressure drop across the unit is 15 psi at maximum flow. Differential pressure should not exceed 45 psi.
These precalibrated flowmeters operate at inlet pressures between 5 and 40 psi and at gas temperatures between 64 and 77°F (18 to 25°C) while maintaining the stated ±1.5% full scale accuracy and linearity. When operating beyond 5 to 40 psi, add ±0.02%/psi full scale; if operating beyond 64 to 77°F (18 to 25°C), add ±0.15%/°C full scale.