Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
- 品牌:美国福禄克
- 货号:
- 产地:美国
- 供应商报价: 面议
- 苏州汇畅金机电设备有限公司 更新时间:2024-05-15 08:29:35
-
企业性质授权代理商
入驻年限第7年
营业执照已审核
- 同类产品数字万用表(54件)
联系方式:杨士波400-697-7518
联系我们时请说明在仪器网(www.yiqi.com)上看到的!
-
为您推荐
- 详细介绍
Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.
The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.
Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.
True RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.
Together, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job.
Fluke 116 HVAC Multimeter with Temperature and Microamps
Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to +50°C Storage temperature -40°C to +60°C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/Resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 VAccuracy ±([% of reading] + [counts]): 0.5% + 2 Auto volts Range/Resolution 600.0 V / 0.1 V Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)AC millivolts¹ True RMS Range/Resolution 600.0 mV / 0.1 mV Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)AC volts¹ True RMS Range/Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 VAccuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)Continuity Range/Resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. Ohms Range/Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩAccuracy 0.9% + 1 Range/Resolution 40.00 MΩ / 0.01 MΩ Accuracy 1.5% + 2 Diode test Range/Resolution 2.000 V / 0.001 V Accuracy 0.9% + 2 Capacitance Range/Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μFAccuracy 1.9% + 2 Range/Resolution > 1000 μF Accuracy 5% + 20% LoZ capacitance Range 1 nF to 500 μF Accuracy 10% + 2 typical Temperature² (Type-K thermocouple) Range/Resolution -40°C to 400°C / 0.1°C Accuracy 1% + 10² Range/Resolution -40°F to 752°F / 0.2°F Accuracy 1% + 18² AC μamps True RMS (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA Accuracy 1.0% + 2 DC μamps Range/Resolution 600.0 μA / 0.1 μA Accuracy 1.0% + 2 Hz (V or A input)² Range/Resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 HzAccuracy 0.1% + 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°FMechanical and General Specifications Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) Weight 550 g Warranty 3 years Fluke 323 True-rms Clamp Meter
Specifications AC current Range 400.0 A Accuracy 2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)AC voltage Range 600.0 V Accuracy 1.5% ±5 digits DC voltage Range 600.0 V Accuracy 1.0% ±5 digits Resistance Range/Resolution 400.0 Ω/ 4000 Ω Accuracy 1.0% ±5 digits Continuity ≤ 70 Ω AC response True-rms Data hold Yes Size H x W x D (mm) 207 x 75 x 34 Max wire diameter 30 mm (600 MCM) Weight 265 g Category rating CAT III 600 V
CAT IV 300 VWarranty Two-year Fluke 116/323 KitFluke 116/323 HVAC Combo Kit
Includes Multimeter and Clamp MeterIncludes: Fluke 116 HVAC Multimeter with Temperature and Microamps Fluke 323 True-rms Clamp Mete- 主要用途
- Fluke 116/62 MAX+技术人员工具组合套件
- Fluke T5-1000 Electrical Tester Kit with Holster and 1
- 19种农残混标(GB23200.116-2019 组I)
- 17种农残混标(GB23200.116-2019 组II)
- 16种农残混标(GB23200.116-2019 组III)
- 17种农残混标(GB23200.116-2019 组V)
- 三氯杀螨砜[116-29-0] Tetradifon 100mg
- Tetradifon Solution 100μg/mL in Acetonitrile 1ML[116-2
- Tetradifon Solution 500μg/mL in Acetone 1ML[116-29-0]
- 2,3,4,5,6-Pentabromodiphenyl ether (BDE 116) Solution
- 白度计 AWM-116
- RayCure GB 23200.116-2019方法净化管