仪器网

欢迎您: 免费注册 仪器双拼网址:www.yiqi.com
首页-资讯-资料-产品-求购-招标-品牌-展会-行业应用-社区-供应商手机版
官方微信
仪器网-专业分析仪器,检测仪器平台,实验室仪器设备交易网 产品导购
VIP企业会员服务升级
仪器/ 产品中心/ 生命科学仪器/ 动物实验仪器/ 其它动物实验仪器/ RAD SOURCE RS-2000辐照仪
收藏  

RAD SOURCE RS-2000辐照仪

为您推荐
详细介绍

RS2000系列生物学X-ray辐照仪,可以直接取代传统铯和钴源同位素辐照仪。在剂量均一性、安全性、稳定性、试验重复性等方面更为,已成为生命科学研究领域中的重要科研工具!目前,欧美各国的生物医学科研机构已较少选择同位素辐照仪,而绿色环保、剂量均匀性更佳的Rad Source公司细胞与动物X-ray辐照仪已成为科研领域;
RS2000系列生物学X-ray辐照仪,拥有众多领xian科技:
ZG反射样品室、高安全性屏蔽技术、射线束过滤技术、杂射线滤出装置、简化易操作触控技术、业内最高的剂量均一性,剂量均一性约为±2.5%,业内**一款≥95%;
剂量率可调:0.1~16Gy/min(=10~1600rad/min =10~1600cGy/min);
创新ZG--Patented* RAD+ chamber --* Patent No; 6,389,099 Rad Source uses validations from NIST to validate their equipment. In the case of our laboratory irradiators (RS 2000) the AAPM guide to laboratory calibration is used. In either case output from Rad Source irradiators is calibrated to international standards insuring its performance anywhere in the world;
RAD SOURCE为生物学X射线辐照仪领域世界领导品牌,科研机构产品,RAD SOURCE被认为是高精密、先进辐照技术及高质量的代表,性能稳定,拥有最大的市场份额与科研用户的好评。
RAD SOURCE RS2000系列产品不但成为了美国本土科研机构的,也得到了世界多国高水平科研机构的广泛认可,如:德国、法国、英国、瑞士、意大利、日本、新加坡等;在全球300多家研究机构和生物制药研发企业中运转,其性能和品质得到了全球市场的充分验证;辐照仪从2009年起正式供应ZG科研机构,已被30多家科研平台所选用,性能和品质也得到了国内用户的广泛认可。
RS2000系列生物学X-ray辐照仪,广泛应用于以下各研究领域
饲养层细胞
干细胞
骨sui移植
肿瘤学
免疫学
DNA损伤相关
信号转导
基因组学
放射生物学
小动物辐照
药物研发
等生物医学领域
Welcome to RAD Source
Since 1997 Rad Source Technologies has been the expert in providing renewable, non-isotope, ionizing radiation replacements for self-shielded gamma irradiators. Currently, there are over 300 renowned hospital, university, and pharmaceutical research institutions using Rad Source X-ray technology. To find out more about our equipment, select your application and you will find equipment specifications, literature references, white papers, training videos, discussion forums, as well as other helpful info;
REASONS WHY THE
RAD SOURCE RS 2000 X-RAY IRRADIATOR
IS THE SYSTEM OF CHOICE FOR YOUR
RESEARCH AND BIOLOGICAL IRRADIATION REQUIREMENTS
The RS 2000 is a research & biological irradiator that features the following advantages:
The RS 2000 is self-contained and requires no external coo领 system
NO Nuclear Site license or secure/shielded room is needed
The RS 2000 is ideal for small animal research when using our patented RAD + reflective cage enclosure. This unique and patented feature provides for a dose rate within the cage of 1.2 Gy/min (120 rads/min or the same as gamma irradiator) and the dose distribution is better than 94% across the entire field (much better than a gamma irradiator). The RAD+ is designed to hold one standard Allentown filtered rearing cage. (Three of which are supplies with the system.) This feature improves animal husbandry by allowing transport and irradiation of the animals inside a filtered environment mitigating cross-contamination issues. Because the animals are irradiated in their cage, multiple mice can be irradiated during one cycle. IF itis important for you to have reproducible results that equate to theirradiation standard of Cesium - the only choice is the RS 2000 with .3mm of Copper filter irradiating at 160 kV AT 25 mA (NEW 225 kV available).
The RS 2000 is ideal for targeted tumor irradiation using our spot beam collimator or custom animal shielding and offers variable dose rates to the target.
For Cells and other research the RS 2000 has dose rates of >5 Gy/min (500 rads/min.) filtered and up to >17 Gy/min unfiltered.
This is the only system available that allows for 160 kV operation @ 25 mA (not “AND or OR” but AT 25 mA)
“Plug and Play” installation: Installation, dose-mapping & in-service in one day.
Mounted on wheels
Footprint 33” X 42” (82.8 cm X 106.7 cm) and weighs 1250 lbs (567 kg).
Simple touch screen operators’ panel for ease of use and operation.
Please review the information on our website: www.radsource.com
Rad Source is the recognized expert in the field of x-ray irradiation. We developed the only US-FDA approved blood irradiator for replacing Cs irradiators and are the leaders in high dose, high volume irradiation systems worldwide
The RS 2000 首ld be the choice for your next
professional quality biological and research irradiator
Features
  ·      “Plug and Play” Installation
  ·      Unit is mounted on caster wheels for easy movement
  ·      Self-contained coo领
  ·      Easy access to built-in calibration port
  ·      Specialized filtration eliminates lower energy X-rays
  ·      Optimal for split-dose delivery
  ·      Easy to use touch screen operation
  ·      CE Marked & Compliant
  ·      Renewable Ionizing Radiation
  ·      No NRC License Required
  ·      No shielded or secure room required
  ·      No disposal costs

部分科研机构文献

     RAD SOURCE RS2000系列产品得到了广泛应用,文献发表在以下期刊:Cancer Res.、BLOOD、PANS、CELL、Stem Cell Biology、JEM、Nature、The Journal of Immunology、Hematology and Stem Cells、Stem Cells、PLoS Biology、Liver、I Int. J. Biol. Sci.、THE JOURNAL OF PHARMACOLOGY AND EXPERIMENTAL THERAPEUTICS、MOLECULAR AND CELLULAR BIOLOGY、Experimental Hematology等。
1、DNA damage checkpoint control in cells exposed to ionizing radiation
NATURE
George Iliakis*,1, Ya Wang2, Jun Guan2 and Huichen Wang2
1Institute of Medical Radiation Biology, University of Essen Medical School, Hufelanstrasse 55, 45122 Essen, Germany; 2Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Philadelphia, PA 19107, USA
2、Ionizing radiation-induced long-term expression of senescence markers in mice is independent of p53 and immune status
CELL
Centre de recherche CHU Ste-Justine, Montre´ al, QC, Canada; 2Lawrence Berkeley National Laboratory, Berkeley, CA, USA
3Buck Institute for Age Research, Novato, CA, USA;4Department of Biochemistry and Molecular Genetics, University of Colorado Denver, School of Medicine, Aurora, CO, USA
3、Nuclear Localization of p38 MAPK in Response to DNA Damage
I Int. J. Biol. Sci. 2009, 5
C. David Wood1, Tina M. Thornton1, Guadalupe Sabio2, Roger A. Davis2,
1. Department of Medicine/Immunobiology Program, University of Vermont, Bur领ton,   VT 05405. USA.
2. Program in Molecular Medicine, University of Massachusetts, Worcester, MA 01605.Correspondence to: Mercedes Rincon
Received: 2009.04.30; Accepted: 2009.06.10; Published: 2009.06.16
4、Passive and Active Mechanisms Trap Activated CD8+ T Cells in the ...
The Journal of Immunology
Six- to 8-wk-old mice were irradiated with 1000 rad (10 Gy) as a single dose from an RS2000
x-ray irradiator (Rad Source; Rad Source Technologies, Coral Springs, FL) and used as recipients.
Mature T cells were depleted from donor bone ...
www.jimmunol.org/cgilcontent/full/172/9/5222
5、Expression of common chromosomal fragile site genes, VVWOX/FRA 16D ..
MOLECULAR CARCINOGENESIS
fluency were irradiated in RS2000 X-ray Irradiator. (Rad Source Technologies, Inc., Boca Raton, FL). Control cells were sham-irradiated in both the UV-. C and ionizing radiation (IR) experiments. For BPDE. treatment,8t-dihydroxy-9 ... doLwiley.com
6、Complete differentiation of CD8+ T cells activated locally within ...  
JEM
6 8-wk-old recipient mice were irradiated with a dose of 10 Gy (1000 rad) using an RS2000 X-ray irradiator (RadSource Technologies). Depletion of mature T lymphocytes from donor bone marrow cells was achieved by incubation with anti-CD4 ...
7、An orally bioavailable parthenolide analog selectively eradicates acute myelogenous leukemia stem and progenitor cells
BLOOD
Monica L. Guzman,1 Randall M. Rossi,1 Sundar Neelakantan,2 Xiaojie Li,1 Cheryl A.
8、Ku86 Modulates DNA Topoisomerase I–Mediated Radiosensitization, but not Cytotoxicity,   in Mammalian Cells
Cancer Res 2005
Shyh-Jen Shih, Tara Erbele, and Allan Y. Chen
Department of Radiation Oncology, University of California Davis Medical Center, Sacramento,California
9、Transcellular biosynthesis of cysteinyl leukotrienes in vivo during mouse peritoneal Inflammation  
PANS
Simona Zarini1, Miguel A. Gijo´ n1, Aaron E. Ransome, Robert C. Murphy2
Department of Pharmacology, University of Colorado Denver, Mail Stop 8303, 12801 East 17th Avenue, Aurora Communicated by K. Frank Austen, Brigham and Women’s Hospital, Boston, MA, April 7, 2009 (received for review February 23, 2009)
10、Irradiation Selects for p53-Deficient Hematopoietic Progenitors
PLoS Biology
Andriy Marusyk1,2¤, Christopher C. Porter1,3, Vadym Zaberezhnyy1 DeGregori1,2,3,4*
Department of Biochemistry and Molecular Genetics, University of Colorado Denver School of Medicine, Aurora, Colorado, United States of America, 2 Program in Molecular Biology, University of Colorado Denver School of Medicine, Aurora, Colorado, United States of America
11、Kupffer cell heterogeneity: functional properties of bone marrow–derived and sessile hepatic
macrophages
BLOOD
Ingo Klein, 1,2 Judith C. Cornejo,3 Noelle K. Polakos,2 Beena John,2 Sherry A.
1David H Smith Center for Vaccine Biology and Immunology, Aab Institute for Biomedical
Research, University of Rochester School of Medicine and Dentistry, NY;
Received February 11, 2007; Accepted July 25, 2007.
12、Irradiation Alters Selection for Oncogenic Mutations in Hematopoietic Progenitors  
Cancer Res 2009
Andriy Marusyk,1,2 Matias Casa′s-Selves,1,2 Curtis J. Henry,1,4 Vadym Zaberezhnyy,1
Jelena Klawitter,5 Uwe Christians,5 and James DeGregori1,2,3,4
1Department of Biochemistry and Molecular Genetics, 2Program in Molecular Biology,
3Department of Pediatrics, 4Integrated
Department of Immunology; and 5Department of Anesthesiology, University of Colorado
Denver School of Medicine, Aurora, Colorado
13、Progression of Pancreatic Adenocarcinoma Is Significantly Impeded with a Combination of
  Vaccine and COX-2 Inhibition1
The Journal of Immunology
Pinku Mukherjee,2* Gargi D. Basu,† Teresa L. Tinder,* Durai B. Subramani,*
Judy M. Bradley,* Million Arefayene,‡ Todd Skaar,‡ and Giovanni De Petris§


产品直通车
X您尚未登录
账号登录
X您尚未登录
手机动态密码登录
X您尚未登录
扫码登录
在线留言
官方微信

仪器网微信服务号

扫码获取最新信息


仪器网官方订阅号

扫码获取最新信息

在线客服

咨询客服

在线客服
工作日:  9:00-18:00
联系客服 企业专属客服
电话客服:  400-822-6768
工作日:  9:00-18:00
订阅商机

仪采招微信公众号

采购信息一键获取海量商机轻松掌控