Dionex Acclaim Carbamate LC Column 液相色谱柱
- 品牌:美国戴安
- 货号:
- 产地:美国
- 供应商报价: 面议
- 上海希言科学仪器有限公司 更新时间:2024-03-27 13:33:47
-
企业性质生产商
入驻年限第6年
营业执照已审核
- 同类产品生物耗材(5878件)
联系方式:李经理13916220072
联系我们时请说明在仪器网(www.yiqi.com)上看到的!
-
为您推荐
- 详细介绍
Acclaim Carbamate LC Column
The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.
- Baseline separation of carbamate pesticides specified in US EPA Method 531.2
- Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
- Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
- High efficiency, extremely low column bleed, and rugged column packing
Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations: 2.1 × 100 mm and 2.1 × 150 mm.
技术参数:
Acclaim Carbamate Column Specifications Column chemistry Proprietary alkyl group Operating pressure limit (recommended) 6000 psi (4000 psi) Operating pH range (recommended) 2.5–8.0 (3.0–7.0) Operating flow rate range (recommended) 0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats订购信息:
Analytical Columns Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm) 075596 Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm) 075597 Acclaim Carbamate, 5?m Analytical (4.6 x 250mm) 072924 Acclaim Carbamate, 3?m Analytical (4.6 x 150mm) 072925 Acclaim Carbamate, 3?m Analytical (3.0 x 150mm) 072926 Acclaim Carbamate, 3?m Analytical (2.1 x 150mm) 072927 Guard Columns Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2) 072928 Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2) 072929 Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2) 072930 Acclaim SST Guard Cartridge Holder V-2 069580 Acclaim Guard Kit (Holder and coupler) V-2 069707 Guard to Analytical Column Coupler V-2 074188 - 主要用途
- 戴安公司生产的仪器主要有离子色谱仪、高效液相色谱仪、快速溶剂萃取仪和氨基酸直接分析仪。其中离子色谱仪凭借着雄厚的技术优势和方法已广泛地应用于各个领域,其市场占有率达80%。全球与离子色谱相关的文章有90%均出自戴安公司生产的离子色谱仪。