仪器网

欢迎您: 免费注册 仪器双拼网址:www.yiqi.com
首页-资讯-资料-产品-求购-招标-品牌-展会-行业应用-社区-供应商手机版
官方微信
中国仪器网资料中心
仪器网/ 技术资料/ 产品资料/ 分析仪器/光谱仪器/ICP-OES/ICP-AES/ Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with

Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with

上传人: 上海科学仪器有限公司 |大小:412.12KB|浏览:2052次|时间:2018-08-16
Standard-compliant element analysis of silicon carbide and mixtures containing silicon carbide with
文档简介

Elementalanalyzersareimportanttoolsforqualitycontrolofawiderangeofproducts.Avarietyofmatrices,suchasceramics,coal,steelorsoil,canbeanalyzedfortheirelementconcentrationswithdifferenttypesofinstruments.TheproductrangeofEltraGmbH,locatednearDüsseldorf,Germany,comprisesanalyzersforC,H,N,S,Oandthermogravimetrywhichallowforthestandard-compliantdeterminationofcarboninvariouschemicalbondings,aswellasoxygenandnitrogeninSiCandinmaterialscontainingSiC.Therequirementswhichhavetobefulfilledforastandard-compliantanalysismay,however,varygreatly,dependingonthedesiredparameters.1IntroductionSiliconcarbidehasahighmeltingpointof2,700°Candisthereforeanimportantrawmaterialforrefractoryandceramicproducts.AnothercharacteristicofSiCisitsresistanceagainstchlorineandstrongacids,alsoathightemperatures.Thankstoahardnessof9.6Mohs,itisalsousedinthemetallurgicalindustryfortheproductionofabrasivesandpolish.TheEuropeanstandardseriesENISO21068(2008)regulatethechemicalanalysisofsiliconcarbideandrawmaterialscontainingsiliconcarbide.Part1dealswithsamp领,part2withthechemicalanalysisofcarbon,siliconandlossofignitionandpart3coversmetalanalysisanddeterminationofoxygenandnitrogenconcentrations.Eltracombustionanalyzersarewellsuitedforthequalitycontrolofrefractoryandceramicproductswhichcontainsiliconcarbide.Thisarticleoutlinesthepossibilitiesandlimitsofelementalanalyzerswhendea领withthesematerials.2ThermogravimetricparametersThedeterminationofthermogravimetricparameterssuchas,forexample,lossofignition,isdescribedinthesecondpartofISO21068.Thermogravimetryisbasedonthecontinuousrecordingofmasschangesasafunctionofacombinationoftime,temperatureandatmosphere.Thestandardclearlydefinestheuseofmufflefurnacesandbalancesforthisprocess.Allmethodsdescribedinthestandarduseadefinedsamplecontainermadeofsteel,ceramicmaterialorplatinumwhichispreheatedattheprescribedtemperaturebetween250°Cand1050°C.Thesampleweightisnotalwaysdefined(e.g.lossondryingLOD250)orrangesfrom25gto1kg(changeofmassinairat200°Cand400°C).Afterweighingthesampleandapplyingthedefinedtemperatureprogram(e.g.forLOI850,heatingupto850°Candmaintainingfor3h),thehotcruciblesneedtocooldowninthedesiccatorandarethenweighed.Thermogravimetricanalyzerswhichareequippedwithacombinationoffurnaceandbalanceconsiderablysimplifythemanualprocedure.Usually,theseanalyzershaveaninteriorchamberwhichcanbeheatedupto1,000°Candaseparateweighingcellintheanalysischamberwhichisconnectedwiththefurnacebyaceramicpedestal.Arotatingcarouselplacesupto19differentsamples,oneaftertheother,onthepedestaltobeweighed.Themarketoffersthermogravimetricanalyzersforbothsmallsamplequantities(e.g.20mg)andquantitiesof5gormore(suchasEltra’sThermostep,fig.1).Byusinganemptyreferencecrucible,thermalbuoyancyiscompensatedandmeasurementscanbecarriedoutreliablyevenathightemperatures.Theceramiccruciblesusuallyhaveavolumeof12ml,allowingforsampleweightsofupto5g.This,however,isnotverypracticalduetothehighfil领level.Sofar,theDINENISO21068-2standarddoesnotmentionautomatedthermogravimetricanalysis.IfathermogravimetricanalyzerisusedforthedeterminationofLOI850(lossonignitionat850°C),thespecificationsofthestandardcanbemettoahighdegree,ifnot1**%.ForaseriesofteststhestandardEuronormCRMNo.781-1wasweighedintocrucibleswhichhadbeenpreheatedto850°CinEltra’sThermostep.Figure2showsatypicalmeasurementcurve,table1containsthecorrespondingresults.Thestandardwasfirstdriedat105°Covernightandthen3crucibleswerefilledwith1geach.TheLOI850valuemeasuredwiththeThermostepcorrelateswellwiththevalueoffreecarbonstipulatedinthestandard.Anadvantageofthethermogravimetricmethodisthefactthatthesamples,afterhavingbeenheated,arenotsubmittedtoambientair;however,duetotheselectedweighingandmeasurementprocessitonlyrepresentsanapproximationtotheISOstandard.Currentlythemethodcannotbeadaptedtofurtherparameterswhichispartlyduetotherequiredhightemperature(LOI1050)resp.tothelargesampleweights(LOI200with1kgsamplevolume).Duetothemissingreferencematerial,validationoftheprocessremainsadifficulttask.3Determinationofthecarboncontent3.1DeterminationoftotalcarbonPart2oftheISO21068seriesalsodescribestheanalysisofsiliconcarbideanditscarboncontent.AcarefuldifferentiationhastobemadebetweenthetotalcarboncontentandtheSiC-boundcarboncontent.Dependingontherelationofthetwobondings,differentanalysismethodsarestipulatedinthestandard.Therearevariouswaystodeterminethetotalcarboncontentinsiliconcarbidesamples,whichdifferinthecombustionmethod(resistanceorinductionfurnace)andinthedetectionmethod.Coulometric,gravimetricandconductometricmethodsdon’trequirecalibration.Thecarboncontentcanbedeterminedbymeasuringtheweight,theelectricchargeortheconductivity.Forthesedetectionmethodstherequirementofchemicalsishigh;moreover,themarketdoesn’tofferadequateinstruments.Alternativeprocedurespermittedbythestandardincludetheuseofelementalanalyzerswithinductionfurnace(EltraCS-800)orresistancefurnace(EltraCS-580)aswellasdetectionwithinfraredcells.AcombinationofthetwocombustiontechnologiesandacombinedusageofthedetectorshavebeenrealizedinEltra’sCS-2000analyzer(fig.3).Fig.3:ELTRA’sCS-2000featurestheuniqueDualFurnaceTechnologyResistancefurnaceswithceramictubeoperateatlowertemperaturesthaninductionfurnaces.Theceramiccombustiontubesallowforamaximumtemperatureof1,500°C.TosafelyoxidatethetotalcarboninthesiliconcarbidetoCO2,resistancefurnacesrequiretheadditionofacceleratorssuchasleadborateortinpowder.Duetoatemperatureofapprox.2,500°Ctheoxidationofsiliconcarbidetendstotakeplacemorequicklyandmorereliablyinaninductionfurnace;moreover,themeasurementresultsshowfewervariations(seetable2).Whereastheacceleratorsfortheresistancefurnacesareusedforoxidation(leadborate)orlocaltemperaturerise(tinpowder),themetalacceleratorsusedininductionfurnacesarerequiredtoensurecombustioninthefirstplace,assiliconcarbidehasnoproperelectricconductivity.Aclearerdefinitionofthecalibrationmethodsforthevariousprocedureswouldbeawelcomeextensionofthestandard.Though[1-2]mentionsuitablecalibrationmaterials,thecalibrationwithgraphiteorcalciumcarbonateisonlydescribedindetailforthedetectionmethodwiththermalconductivitycells(chapter5.4.5).Theresultsshownintable2wereobtainedbycalibrationwithgraphite.3.2DeterminationoffreecarbonThisparametercanbeeasilydeterminedwithelementalanalyzers.Thestandardstipulatestheuseofananalyzerwithresistancefurnaceandinfrareddetection;howeverthedirectdeterminationislimited(chapter6.4.1).Astheupperlimitforthefreecarboncontentisgivenwith2%,analysissolelybycombustion,forexampleoftheEuronormstandardCRM781-1withaninformativevalueof37.22%isnotpermitted.Thus,characterizationoffreecarbonbydirectcombustionispracticallylimitedtopuresiliconcarbide.Tomeasureverylowconcentrations,thestandardspecifiestheuseofaquartztube(asisused,forexample,inEltra’sCW-800analyzer).Theanalyzerdescribedinchapter3.1ofthisarticleisnotsuitableforthisapplication;duetotheusageofdifferentfurnaces,ceramictubescannotsimplybeexchangedforquartztubes.Duetotheirpermeablestructureceramictubesarenotsuitedforthedeterminationofverylowconcentrations.Table3showstheresultsofastandardcompliantanalysisofthereferencematerialBAM-S003andadditionallyoftheEuronorm781-1standard,carriedoutwithEltra’sCW-800.Thestandardwasalsomeasuredwithananalyzerwithceramiccombustiontube(EltraCS-580).Theresultsintable3clearlysupporttheusageofafurnacewithquartztubewhenanalyzinglowcarbonconcentrations.Iftheconcentrationsaresufficientlyhigh,analyzerswithceramictubescanalsoprovidemeaningfulmeasurementresults.Inthiscase,thecalibrationoftheelementalanalyzerisofgreatimportance.Whereashigherconcentrationscanbeeasilycalibratedwithgraphite(1**%carbon)orpurecalciumcarbonate(12%carbon),lowconcentrationscanonlybecalibratedeitherwithanexpensivereferencematerialorasyntheticcarbonstandard.3.3DeterminationofthesiliconcarbidecontentTheSiCcontentcanbedeterminedfromthedifferencebetweentotalcarbonandfreecarboncontent;however,thisisonlypermissiblewhenthefreecarboncontentis50%orlessofthetotalcarboncontent.Thisapplies,forexample,totheBAMS-003standardbutnottoCRM781-1.Iftherelationbetweenfreeandboundcarbonismorethan25%,adirectanalysisispossible.IftheCRM781-1sampleisfreedofsurfacecarbon(table3),itcanbeanalyzeddirectlywithaninductionorresistancefurnace(table4).4AnalysisofoxygenandnitrogenThethirdpartoftheDINEN21068seriesdealswiththedeterminationofoxygenandnitrogen.Incontrasttothedeterminationofcarbonspecies,thesampleneedstobeheatedinaninertgasflow(helium)tomeasureitsoxygenandnitrogencontent.Theinertgasfusionmethodhasbeenestablishedformanyyearsandisalsousedforanalyzingmetals.Thestipulatedtemperatureofapprox.2,800°Ccanonlyberealizedinanelectrode/impulsefurnace.Anupperandalowerelectrodeapplyvoltagetothegraphitecruciblecontainingthesamplewhichhaspreviouslybeenpurgedwithinertgas.Theanalysisqualityisstronglyinfluencedbythepowerlineavailable(approx.5kWrecommended)andthepurityofthefluxused(nickelbasketsorcapsules).Thesematerialsarebasicallyusedformeltingpointreductiontoreleasethegassescontainedinthesiliconcarbidefromthemoltensample.Table5showstheresultsfortheBAMS-003standardobtainedwithEltra’sONH-2000analyzer.Theanalysiswascarriedoutwithpre-edgednickelbasketsanda5kWpowerline.Aftercalibrationwithacertifiedsteelstandard,goodcompliancewiththecertified/informativevalueswasachieved.Primarysubstances(suchasKNO3)canalsobeusedforcalibration;however,thesesubstancesneedtobedissolvedanddilutedfirst,andarethendriedinnickelcapsules.Themeasuringprincipledoesnotallowfordirectanalysisofliquidstandards.Theinertgasfusionprocedurecanbeeasilyappliedtotheanalysisofotherceramicswithhighnitrogen(e.g.Si3N4)oroxygen(e.g.SiO2,ZrO2)content.5ConclusionAcomprehensiveanalysisofsiliconcarbideandmixturescontainingsiliconcarbideinaccordancewiththeDINENISO21068standardseriesinvolvessophisticatedtechnicalequipment.Ifthedeterminationofmetals,notelaboratedoninthisarticle,istakenintoaccountaswell,theadditionaluseofspectrometers(ICP,OES,XRF)iscalledfor.Themarketoffersanalyzersforstandard-compliantanalysisofcarbonconcentrations;however,differentanalysisspecificationsrequiredifferentconfigurations(inductionfurnace,combustioninceramicorquartzglasstube).Oxygenandnitrogenareeasilyandreliablydeterminedwithanalyzersusinginertgasfusion.Forafutureupdateofthestandardamoreextensivetreatmentofthermogravimetricmethodswouldbehighlyrecommendable.ModernTGAanalyzersnotonlyreducehumanerrorsthroughautomizationbut,thankstoflexibleuseofcarriergasandtemperatures,providemanifoldpossibilitiestocharacterizeSiCandrelatedproducts.Author:Dr.AndreKlostermeierProductManagerELTRAGmbHPhone:+49(0)2104/2333-300E-Mail:a.klostermeier@eltra.comLiterature[1]RmpChemieLexikon,10thedition(2002)[2]ENISO21068(2008),Parts1,2,3
标签:

您可能感兴趣的资料
立即上传
该会员其他文档
相关其他文档
看过此文档还看过
X您尚未登录
账号登录
X您尚未登录
手机动态密码登录
X您尚未登录
扫码登录
在线留言
官方微信

仪器网微信服务号

扫码获取最新信息


仪器网官方订阅号

扫码获取最新信息

在线客服

咨询客服

在线客服
工作日:  9:00-18:00
联系客服 企业专属客服
电话客服:  400-822-6768
工作日:  9:00-18:00
订阅商机

仪采招微信公众号

采购信息一键获取海量商机轻松掌控