Masterflex Gas Mass Flowmeter Controller; 0 to 500 sccm
- 品牌:美国Masterflex
- 型号:
- 产地:美国
- 供应商报价: ¥ 13137.5
- 上海科学仪器有限公司 更新时间:2024-05-13 14:01:15
-
企业性质
入驻年限第9年
营业执照
- 同类产品
-
为您推荐
- 详细介绍
- Integrated valve allows precise flow control
- Accepts a 0 to 5 VDC input signal for remote valve control
- Calibrated for air and nitrogen
- Maximum flow rate of 0.5 LPM
规格与描述
- 重复性±0.5% full-scale
- 准确性±1.5% full-scale
- 最高压力 (psi)150
- 最小流速 (LPM)0
- 最大流速 (LPM)0.5
- 最大流速 (mL/min)500
- 材料Acetal;Viton;Anodized Aluminum
- 触液材料Anodized Aluminum, 316 Stainless Steel, Viton, Acetal
- ZD工作温度 (° F)50
- 最高工作温度 (° F)122
- 最高工作温度 (° C)50
- 工艺连接件1/8" Compression
- 最大流量条件下压降 (PSID)15
- 漏气率1 X 10-4 sccs He (max)
- 气体类型Air, Nitrogen
- Media TypeAir;Nitrogen
- 最大粒径 (µm)20
- 响应时间 (ms)2000
- 输出Linear 0 to 5 VDC (2500 Ω minimum load)
- 显示类型None
- 已认证No
- 描述Controller without display, 0 to 500 sccm
包括
Two acetal compression fittings and a 24" cable with hub connector.
主要特点
- Accepts a 0 to 5 VDC input signal for remote valve control
- Calibrated for air and nitrogen
- Maximum flow rate of 0.5 LPM
关于该商品的更多信息
These low-cost mass flowmeter controllers use a thermal gas flow sensing technique that results in highly accurate readings and repeatability. The controllers accept a 0 to 5 VDC input signal for remote valve control. Controllers with LCD display feature a potentiometer for manual valve control. The 3 1/2"-digit display tilts up to 90° for easy viewing. Front panel dip switch lets you select one of the factory programmed gases: air or nitrogen.
All controllers require a combined power supply/input/output cable. This cable combines three functions into one unit: power source, plus input or output of 0 to 5 VDC signals. Use the input signal for remote valve control; use the output signal for datalogging or controlling other instruments. Order the power supply/input/output cable separately.
Wetted materials are anodized aluminum, 316 stainless steel, brass, Viton®, and acetal. Maximum pressure drop across the unit is 15 psi at maximum flow. Differential pressure should not exceed 45 psi.
These precalibrated flowmeters operate at inlet pressures between 5 and 40 psi and at gas temperatures between 64 and 77°F (18 to 25°C) while maintaining the stated ±1.5% full scale accuracy and linearity. When operating beyond 5 to 40 psi, add ±0.02%/psi full scale; if operating beyond 64 to 77°F (18 to 25°C), add ±0.15%/°C full scale.
- Masterflex Gas Mass Flowmeter Controller; 0 to 50 sccm
- Masterflex Gas Mass Flowmeter Controller; 0 to 100 scc
- Masterflex Aluminum gas mass flow transmitter, 500 sL/
- ASTM Methods D4420/D5580 Aromatics in Gasoline by Gas
- ASTM Methods D4420/D5580 Aromatics in Gasoline by Gas
- Purgeable Arom. for Gas.Ident.Mix 3,200ug/ml 标准品
- Gas collection tubes 150 ml, with 2 straight stopcocks
- PerkinElmer Avio 500 ICP-OES
- 珀金埃尔默Avio 500电感耦合等离子体发射光谱仪ICP-OES
- 珀金埃尔默 PinAAcle 500 Flame 原子吸收光谱仪
- 珀金埃尔默PinAAcle 500原子吸收光谱仪
- 赛默飞Triplus 500 GC顶空自动进样器