Masterflex Vortex Flowmeter with Temperature, 1/2" NPT(F); 0.93 to 13.2 GPM
- 品牌:美国Masterflex
- 型号:
- 产地:美国
- 供应商报价: ¥ 3350
- 上海科学仪器有限公司 更新时间:2024-04-17 14:51:26
-
企业性质
入驻年限第9年
营业执照
- 同类产品
-
为您推荐
- 详细介绍
- Built-in 1000 Ω RTD sensor provides direct temperature measurement of media
- Deigned with rugged PPA molded construction for enhanced durability
- Excellent media compatibility with ETFE, EPDM, and PPD wetted parts
- Use with low viscosity liquids for laboratory and industrial applications
规格与描述
- 准确性Up to 50% of max flow: ±1% of reading; over 50% of max flow: ±2% of reading
- ZD工作温度 (° F)5
- ZD工作温度 (° C)-15
- 最高工作温度 (° F)185
- 最高工作温度 (° C)85
- 最大流量条件下压降 (PSID)3
- 电子连接M12x1, 5-pole DC microconnector
- 输出 (电压)Yes
- 输出Square 5 V digital wave pulse
- 描述Vortex Flowmeter for Liquids, 0.93 to 13.2 GPM / 3.5 to 50 LPM
主要特点
- Deigned with rugged PPA molded construction for enhanced durability
- Excellent media compatibility with ETFE, EPDM, and PPD wetted parts
- Use with low viscosity liquids for laboratory and industrial applications
关于该商品的更多信息
These economical vortex flowmeters are suitable for water and water glycol-based heat exchange systems. The transmitters work on the vortex shedding flow principle. As flow velocity increases, alternating vortices are formed on each side of the bluff body within the flowtube and travel downstream. The flowmeters utilize piezoelectric sensors embedded in a vane downstream from the bluff to detect the vortices and transfer the sensed vortices into flow velocity. A flow factor is provided to convert frequency to volumetric flow rate for each size of flowmeter. Flowmeters have a PT1000 RTD for temperature measurement of the media
Note: Media with viscosity greater than 2 centipose will require higher flow rates to form measurable vortices within the flowtube.
- Masterflex Vortex Flowmeter with Temperature, 1/4" NPT
- Masterflex Vortex Flowmeter with Temperature, 1" NPT(F
- Masterflex Printed Microscope Slide, one rectangular s
- Cole-Parmer Polystat Low-Temperature Benchtop Recircul
- Ashcroft T7 Temperature Switch Remote Mount 5' CAPIlla
- Ashcroft T7 Temperature Switch Remote Mount 5' CAPIlla
- Ashcroft T7 Temperature Switch Remote Mount 5' CAPIlla
- EPA Method 8270 Appendix IX Mixture 1 with Phentermine
- ASTM Method D6296 Calibration Standard with Methyl ter
- ASTM Method D6296 Calibration Standard with ETBE in Is
- ASTM Method D3798 p-Xylene Impurity Standard with IS
- SPHERICAL JOINTS, BALL MEMBERS, S 13/2 DURAN, 8 X 10