仪器网

欢迎您: 免费注册 仪器双拼网址:www.yiqi.com
首页-资讯-资料-产品-求购-招标-品牌-展会-行业应用-社区-供应商手机版
官方微信
仪器网-专业分析仪器,检测仪器平台,实验室仪器设备交易网 产品导购
VIP企业会员服务升级
仪器/ 产品中心/ 仪器专用耗材配件/ 其它/ 其它仪器专用配件/ Pierce™ Protein Concentrator PES, 10K MWCO, 2-6 mL
收藏  

Pierce™ Protein Concentrator PES, 10K MWCO, 2-6 mL

联系方式:实验室产品和服务4008558699转8056

联系我们时请说明在仪器网(www.yiqi.com)上看到的!

为您推荐
详细介绍
描述 Thermo Scientific™ Pierce™ Protein Concentrators PES are disposable ultrafiltration centrifugal devices with a polyethersulfone (PES) membrane for concentration, desalting, and buffer exchange of biological samples. This product has a molecular weight cutoff (MWCO) of 10K and can be used for processing sample volumes ranging from 2 to 6 mL.

Features of Pierce Protein Concentrators PES:

• Rapid protein concentration—sample concentration of 10- to 30-fold can be achieved in 5 to 30 minutes for 10K MWCO (time may vary for a product with a different MWCO)
• Excellent protein recovery—typical protein recovery is >90%
• Versatility—perform sample concentration, diafiltration, or buffer-exchange of biological samples
• Compatibility—may be used in both fixed angle and swing bucker rotors; collect and recover sample without invert spinning

For easy identification, the MWCO value is etched on the side of each device. To assist with sample addition and recovery, a clear window with graduations is located on the side of each device enabling visual determination of the retentate volume. The vertical design of the membrane allows high flux rates, low nonspecific binding, and negligible protein aggregation on the membrane; and it offers reliable and consistent results.

Pierce Protein Concentrators PES contain a membrane rated for retaining molecules with a molecular weight at least 2-fold greater than the MWCO rating of the PES membrane within the device. Reduced recovery may occur when using a concentrator with molecules smaller than the recommended mass. Protein recovery will vary depending on the specific protein in the sample and its starting concentration. To achieve >90% recovery of protein, the minimum protein sample concentration should be 0.1 mg/mL.
For Research Use Only. Not for use in diagnostic procedures.
图表
Processing time and protein recovery using 2-6 mL concentrators
6 mL volumes of four different protein solutions were concentrated over 30-fold in a swinging bucket rotor at 4,000 x g at 25°C, using 3K, 10K, 30K, or 100K MWCO Pierce Protein Concentrators PES (2-6 mL)." data-omni-action="View figure"> Processing time and protein recovery using 2-6 mL concentrators

Processing time and protein recovery using 2-6 mL concentrators

Comparison of flux curves for different MWCOs using 2-6 mL concentrators
Protein samples for each MWCO (3K, 10K, 30K, 100K) at approximately 0.25 mg/mL starting concentration were centrifuged in 2-6 mL Pierce Protein Concentrators PES at 3,000 x g for 90 min to determine the protein concentration rate. For 10K, 30K, and 100K MWCOs, >90% of the protein solution was concentrated within 15 min; for the 3K MWCO, this degree of concentration occurred within 90 min." data-omni-action="View figure"> Comparison of flux curves for different MWCOs using 2-6 mL concentrators

Comparison of flux curves for different MWCOs using 2-6 mL concentrators

厂商相关其他产品
X您尚未登录
账号登录
X您尚未登录
手机动态密码登录
X您尚未登录
扫码登录
在线留言
官方微信

仪器网微信服务号

扫码获取最新信息


仪器网官方订阅号

扫码获取最新信息

在线客服

咨询客服

在线客服
工作日:  9:00-18:00
联系客服 企业专属客服
电话客服:  400-822-6768
工作日:  9:00-18:00
订阅商机

仪采招微信公众号

采购信息一键获取海量商机轻松掌控