-
-
泊睿BR-PV-THD热循环-湿热-湿冻试验箱
- 品牌:上海泊睿
- 型号: BR-PV-THD系列
- 产地:上海
- 供应商报价: ¥ 360000
- 上海泊睿科学仪器有限公司
-
企业性质
入驻年限第10年
营业执照
- 同类产品
-
为您推荐
- 详细介绍
★技术参数
☆温度范围:
A型:-20℃~+100℃(+150℃)
B型:-40℃~+100℃(+150℃)
C型:-60℃~+100℃(+150℃)
D型:-70℃~+100℃(+150℃)
☆温度波动度:±0.5℃
☆温度均匀度:±2.0℃
☆湿度范围:30%~98%R.H
☆湿度误差:+2/-3%R.H
★型号及工作室尺寸(D×W×H)(mm)
GDJ-100400×450×550
GDJ-150500×500×600
GDJ-225500×600×750
GDJ-400600×800×850
GDJ-800800×1000×1000
GDJ-10001000×1000×1000
GDJ-15001500×1000×1000BR-PV-THD Thermal Cyc领, Humidity-Freeze, Damp-Heat Tester
Thermal Cyc领 Test
Implementation of standards: IEC 61215:2005 & Ed.3, IEC 61646:2008 “TC200 thermal cyc领 test, TC50 thermal cyc领 test”, and UL 1703-2008 “temperature cyc领 test”.
1. IEC 61215 Ed.3, IEC 61646:2008 test condition:
The temperature of modules between -40°C±2°C and +85°C±2°C cyc领, the rate of change of temperature between the low and high extremes shall not exceed 100°C/h and the module temperature shall remain stable at each extreme for a period of at least 10 min. The cycle time shall not exceed 6h.
2. UL 1703-2008 test condition:
The temperature of modules between -40°C±2°C and +90°C±2°C cyc领, the instantaneous rate of temperature change of the test chamber with respect to time is not to be greater than 120°C/h.
Humidity-Freeze Test
Implementation of standards:
IEC 61215 Ed.3, IEC 61646:2008 “humidity-freeze”, UL 1703-2008 “humidity test”
The temperature of modules between -40°C±2°C and +85°C±2°C cyc领.
Relative humidity 85%RH±5% at 85°C in IEC 61215 and 61646, but UL 1703 Control in 85%RH±2.5% at 85°C, allowable deviation range different.
Damp-Heat Test
Implementation of standards: IEC 61215:2005 & Ed.3, IEC 61646:2008 “damp-heat test”
Test temperature 85°C ± 2°C, Relative humidity 85% ± 5%, Test duration 1000h
Electrical continuity, Insulation continuity, Grounding continuity test system:
Implementation of standards: IEC 61215:2005 & Ed.3, IEC 61646:2008 “electrical continuity for TC200 thermal cyc领 test and humidity-freeze test” condition, and UL 1703-2008 “Insulation continuity and grounding continuity” condition.
DC power current / voltage output: ≥10A / 50VModule type Imp TC 200 Thermal Cyc领 Humidity-Freeze 1.58×0.808m
monocrystalline5.20A Provide Im over 25°C
Provide 0.1~0.5A below 25°CProvide current during the whole test 2×1m
polycrystalline7.66A Provide Im over 25°C
Provide 0.1~0.5A below 25°CProvide current during the whole test 1.4×1.1m
Thin-film1.66A Provide current during the whole test Provide current during the whole test 2.6×2.2m
Thin-film2.66A Provide current during the whole test Provide current during the whole test