产品详情:

?

产品名称:Glass Inlet Liners
仪器厂商:PerkinElmer/美国 珀金埃尔默
价格:面议
库存:是

Capillary Split/Splitless Injector Liners
Description ID mm OD mm Length mm Pkg Part no.
PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) General purpose use, ideal for chlorinated pesticides analyses 2 4 86.2 5 N6502001
Split Glass Liner Siltek Deactivated Surface Liner (with wool) Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken 4 6.2 92.1 5 N6121020
Split Glass Liner (with wool) Universal liner for general purpose analyses 4 6 92.1 5 N6502009
Split Siltek Deactivated Glass Liner (with wool) Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 4 6 92.1 5 N6502010
Clarus Cup Split Glass Liner Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean 4 6 92.1 5 N6502011
Clarus Cyclosplitter Glass Liner Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections 4 6 92.1 5 N6502012
Uniliner Deactivated Glass Liner (with wool) Universal liner or general purpose analyses 4 6.2 92.1 5 N6121022
Clarus Splitless Glass Liner Low volume sample analyses, beneficial with headspace and purge/trap 1 6.2 92.1 5 N6502006
Quartz Liner for Splitless Operation (ships with instrument) Standard injector liner 2 6.2 92.1 1 N6121002
Glass Liner for Splitless Operation Universal liner for general purpose analyses 2 6.2 92.1 1 N6101372
Deactivated Glass Liner for Splitless Operation (with wool) Good for analyses of trace samples 2 6.2 92.1 5 N6121021
Siltek Deactivated Liner (with wool) for Splitless Operation Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken 2 6.2 92.1 5 N6502004
Quartz Liner for Split Operation Good for large volume injection samples 4 6.2 92.1 1 N6121001
Glass Liner for Split Operation Universal liner for general purpose analyses 4 6.2 92.1 1 N6101052
Siltek Deactivated Double Gooseneck Glass Liner (with wool) Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems 4 6.2 92.1 5 N6502003
Cyclo Double Gooseneck Liner for Split Operation Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean 4 6.2 92.1 5 N6502005
Zero Dilution Glass Outer Liner Ideal for trace HS work. Use in conjunction with N1011446 2 6.3 90 1 N1011445
Zero Dilution Glass Inner Liner Ideal for trace HS work. Use in conjunction with N1011445 2 6.3 90 1 N1011446
Programmed Temperature Split/Splitless (PSS) Injector Liners
Quartz Liner for Splitless operation (ships with instrument) Excellent liner for low volume analyses 1 4 86.2 1 N6121006
NEW! Siltek Deactivated Glass PSS Liner Used for low volume trace sample analyses 1 4 86.2 5 N6502000
Quartz Liner for Split operation (ships with instrument) Approved PerkinElmer standard injector liner 2 4 86.2 1 N6121004
NEW! Siltek Deactivated Glass Liner for Split operation (with wool) Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken 2 4 86.2 5 N6502001
NEW! Siltek Deactivated Glass Liner for Split operation Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range 2 4 86.2 5 N6502002
Zero Dilution Outer Liner Use in conjunction with N1011446 2.8 4 83 1 N1011447
Zero Dilution Inner Liner Use in conjunction with N1011447 2 73 1 N1011446
On-column Glass Liner 2.4 4 86.2 1 N6101539
Liner/Hour Glass for POC Injector 2.4 4 19.05 1 N6101703
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 1 N6121008
Quartz Split Liner with Silanized Glass Wool 2 4 86.2 5 N6121009
Packed Column Injector Liners
Drilled Uniliner (hole on top) Excellent liner for high sample recovery and linearity, recommended for aqueous injections. 4 6.2 92.1 5 N6121022
NEW! Drilled Uniliner (hole on bottom) Recommended for analysis in which compounds of interest could be affected by a tai领 solvent peak. Good for PPC equipped GCs 4 6.2 92.1 5 N6502013
NEW! Gooseneck Drilled Uniliner (hole on top) Use for trace,active samples, high recovery and linearity 4 6.2 92.1 5 N6502014
NEW! Gooseneck Drilled Uniliner (hole on bottom) Use for trace, active samples, high recovery and linearity 4 6.2 92.1 5 N6502015
NEW! Open Top Uniliner (with wool) Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue 4 6.2 92.1 5 N6502016
NEW! Cyclo Uniliner Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction 4 6.2 92.1 5 N6502017
Wide-Bore Column Glass Liner 6 4 92.1 1 N6101375
Wide-Bore Column On/Off Quartz Liner 6 4 92.1 1 N6121003
Colored Injector Liners
PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility 2 4 86.2 5 N9306232
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306233
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 1 N9306234
Capillary splitless deactivated glass liners with deactivated wool. 4 6.2 92.1 5 N9306235
Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample. 4 6.2 92.1 5 N9306236
PSS Splitless deactivated glass liners with deactivated wool 5/pk. 1.25 4 86.2 5 N9306237

您可能感兴趣的产品

北京博德恒悦科贸有限公司为你提供Glass Inlet Liners N6121022,N6502013,N6502014,N6信息大全,包括Glass Inlet Liners N6121022,N6502013,N6502014,N6价格、型号、参数、图片等信息;如想了解更多产品相关详情,烦请致电详谈或在线留言!
  • 相关品类
  • 同厂商产品

您可能还在找

新品推荐

红外压片模具/溴化钾压片模具

主要特点: -操作简便,适用于红外等样品制作 -可制做高质量的溴化钾压片 -承受压力12吨 -其它规格型号可选

实验室液压压片机

主要特点: -手动操作 -蓝色机身,白色基座 -紧凑型设计,节省实验室空间 -广泛应用于红外光谱及其它样品压片 -适用于不同尺寸的模具 -压力实时显示 -不锈钢材质的压盘 -操作方便,容易维护

实验室液压压片机

主要特点: -手动操作 -蓝色机身,白色基座 -紧凑型设计,节省实验室空间 -广泛应用于红外光谱及其它样品压片 -适用于不同尺寸的模具 -压力实时显示 -不锈钢材质的压盘 -使用安全,配有安全防护窗 -操作方便,容易维护