产品名称:Glass Inlet Liners
仪器厂商:PerkinElmer/美国 珀金埃尔默
价格:面议
库存:是
| Capillary Split/Splitless Injector Liners | |||||
| Description | ID mm | OD mm | Length mm | Pkg | Part no. |
| PSS Splitless Glass Liner Siltek Deactivated Surface Liner (with wool) General purpose use, ideal for chlorinated pesticides analyses | 2 | 4 | 86.2 | 5 | N6502001 |
| Split Glass Liner Siltek Deactivated Surface Liner (with wool) Universal liner for general purpose analyses. Surface provides inertness over a wide sample pH range. Wool can be adsorp -tive if fibers are broken | 4 | 6.2 | 92.1 | 5 | N6121020 |
| Split Glass Liner (with wool) Universal liner for general purpose analyses | 4 | 6 | 92.1 | 5 | N6502009 |
| Split Siltek Deactivated Glass Liner (with wool) Universal liner for general purpose analyses. Deactivated surface provides minimal bleed and inertness over a wide sample pH range | 4 | 6 | 92.1 | 5 | N6502010 |
| Clarus Cup Split Glass Liner Good for both high and low molecular weight compounds. Sample vaporization is aided by tortuous flow path and minimizes molecular weight discrimina -tion. Difficult to clean | 4 | 6 | 92.1 | 5 | N6502011 |
| Clarus Cyclosplitter Glass Liner Patented cylindrical design for dirty samples, easy to clean and allows many injections before cleaning is required. Not recommended for large volume injections | 4 | 6 | 92.1 | 5 | N6502012 |
| Uniliner Deactivated Glass Liner (with wool) Universal liner or general purpose analyses | 4 | 6.2 | 92.1 | 5 | N6121022 |
| Clarus Splitless Glass Liner Low volume sample analyses, beneficial with headspace and purge/trap | 1 | 6.2 | 92.1 | 5 | N6502006 |
| Quartz Liner for Splitless Operation (ships with instrument) Standard injector liner | 2 | 6.2 | 92.1 | 1 | N6121002 |
| Glass Liner for Splitless Operation Universal liner for general purpose analyses | 2 | 6.2 | 92.1 | 1 | N6101372 |
| Deactivated Glass Liner for Splitless Operation (with wool) Good for analyses of trace samples | 2 | 6.2 | 92.1 | 5 | N6121021 |
| Siltek Deactivated Liner (with wool) for Splitless Operation Optimum sample dispertion for active samples. Surface provides inertness over a wide sample pH range. Wool can be adsorptive if fibers are broken | 2 | 6.2 | 92.1 | 5 | N6502004 |
| Quartz Liner for Split Operation Good for large volume injection samples | 4 | 6.2 | 92.1 | 1 | N6121001 |
| Glass Liner for Split Operation Universal liner for general purpose analyses | 4 | 6.2 | 92.1 | 1 | N6101052 |
| Siltek Deactivated Double Gooseneck Glass Liner (with wool) Optimum sample dispertion for active samples. Decreases breakdown of active compounds such as endrin and DDT. Chamber contains sample vaporization cloud. Not suitable for PPC systems | 4 | 6.2 | 92.1 | 5 | N6502003 |
| Cyclo Double Gooseneck Liner for Split Operation Cylindrical design for large volume and trace dirty samples. Decreases injection port discrimination. Cannot be packed with wool and more difficult to clean | 4 | 6.2 | 92.1 | 5 | N6502005 |
| Zero Dilution Glass Outer Liner Ideal for trace HS work. Use in conjunction with N1011446 | 2 | 6.3 | 90 | 1 | N1011445 |
| Zero Dilution Glass Inner Liner Ideal for trace HS work. Use in conjunction with N1011445 | 2 | 6.3 | 90 | 1 | N1011446 |
| Programmed Temperature Split/Splitless (PSS) Injector Liners | |||||
| Quartz Liner for Splitless operation (ships with instrument) Excellent liner for low volume analyses | 1 | 4 | 86.2 | 1 | N6121006 |
| NEW! Siltek Deactivated Glass PSS Liner Used for low volume trace sample analyses | 1 | 4 | 86.2 | 5 | N6502000 |
| Quartz Liner for Split operation (ships with instrument) Approved PerkinElmer standard injector liner | 2 | 4 | 86.2 | 1 | N6121004 |
| NEW! Siltek Deactivated Glass Liner for Split operation (with wool) Maximum inertness and packed with wool gives opti-mum sample dispersion. Surface provides inertness over wide sample pH range. Wool can be adsorptive if fibers are broken | 2 | 4 | 86.2 | 5 | N6502001 |
| NEW! Siltek Deactivated Glass Liner for Split operation Max. inertness gives optimum sample dispersion. Deactivated surface provides minimal bleed and inertness over a wide sample pH range | 2 | 4 | 86.2 | 5 | N6502002 |
| Zero Dilution Outer Liner Use in conjunction with N1011446 | 2.8 | 4 | 83 | 1 | N1011447 |
| Zero Dilution Inner Liner Use in conjunction with N1011447 | 2 | 73 | 1 | N1011446 | |
| On-column Glass Liner | 2.4 | 4 | 86.2 | 1 | N6101539 |
| Liner/Hour Glass for POC Injector | 2.4 | 4 | 19.05 | 1 | N6101703 |
| Quartz Split Liner with Silanized Glass Wool | 2 | 4 | 86.2 | 1 | N6121008 |
| Quartz Split Liner with Silanized Glass Wool | 2 | 4 | 86.2 | 5 | N6121009 |
| Packed Column Injector Liners | |||||
| Drilled Uniliner (hole on top) Excellent liner for high sample recovery and linearity, recommended for aqueous injections. | 4 | 6.2 | 92.1 | 5 | N6121022 |
| NEW! Drilled Uniliner (hole on bottom) Recommended for analysis in which compounds of interest could be affected by a tai领 solvent peak. Good for PPC equipped GCs | 4 | 6.2 | 92.1 | 5 | N6502013 |
| NEW! Gooseneck Drilled Uniliner (hole on top) Use for trace,active samples, high recovery and linearity | 4 | 6.2 | 92.1 | 5 | N6502014 |
| NEW! Gooseneck Drilled Uniliner (hole on bottom) Use for trace, active samples, high recovery and linearity | 4 | 6.2 | 92.1 | 5 | N6502015 |
| NEW! Open Top Uniliner (with wool) Packed with fused silica wool, highly recommended for high molecular weight active samples. The fused silica wool traps dirt and sample residue | 4 | 6.2 | 92.1 | 5 | N6502016 |
| NEW! Cyclo Uniliner Cylindrical design for high molecular weight samples provides an excellent vaporization surface. Spiral traps dirt reducing further residue sample interaction | 4 | 6.2 | 92.1 | 5 | N6502017 |
| Wide-Bore Column Glass Liner | 6 | 4 | 92.1 | 1 | N6101375 |
| Wide-Bore Column On/Off Quartz Liner | 6 | 4 | 92.1 | 1 | N6121003 |
| Colored Injector Liners | |||||
| PSS deactivated glass liners with deactivated wool. Narrow bore and quartz wool increase volatilization and reproducibility | 2 | 4 | 86.2 | 5 | N9306232 |
| Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 5 | N9306233 |
| Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 1 | N9306234 |
| Capillary splitless deactivated glass liners with deactivated wool. | 4 | 6.2 | 92.1 | 5 | N9306235 |
| Capillary splitless deactivated glass liners with deactivated wool. Quartz wool is used to fully vaporize the sample. | 4 | 6.2 | 92.1 | 5 | N9306236 |
| PSS Splitless deactivated glass liners with deactivated wool 5/pk. | 1.25 | 4 | 86.2 | 5 | N9306237 |
报价:面议
已咨询121次标准品
报价:面议
已咨询139次标准品
报价:面议
已咨询78次标准品
报价:面议
已咨询86次标准品
报价:面议
已咨询87次标准品
报价:面议
已咨询64次标准品
报价:面议
已咨询86次标准品
主要特点: -操作简便,适用于红外等样品制作 -可制做高质量的溴化钾压片 -承受压力12吨 -其它规格型号可选
主要特点: -手动操作 -蓝色机身,白色基座 -紧凑型设计,节省实验室空间 -广泛应用于红外光谱及其它样品压片 -适用于不同尺寸的模具 -压力实时显示 -不锈钢材质的压盘 -操作方便,容易维护
主要特点: -手动操作 -蓝色机身,白色基座 -紧凑型设计,节省实验室空间 -广泛应用于红外光谱及其它样品压片 -适用于不同尺寸的模具 -压力实时显示 -不锈钢材质的压盘 -使用安全,配有安全防护窗 -操作方便,容易维护