仪器简介:

在飞行时间质谱领域,从MALDI-TOF、QqTOF到LC/TOF-MS以及GC/TOF-MS,Signal Recovery能提供高质量的数据采集产品。



技术参数:

1 GHz preamplifier for timing applications with pulses from ultra-fast detectors, such as microchannel plates, microchannel-plate photomultipliers, channeltrons, silicon diodes, photomultipliers, and electron multipliers
50 W input and output impedance
AC coupled
350 ps rise time
Voltage Gain x100 (50-150;50-ohm;non-inverting)
100 kHz to 1 GHz frequency response
Two identical outputs deliver 0 to -2V pulses into 50 W loads



主要特点:

General
The Model 9306 1 GHz Preamplifier is optimized for fast timing and counting applications with detectors that deliver pulses with ultra-fast rise times. An output rise time of 350 ps and a non-inverting voltage gain of x100 make the Model 9306 ideal for use with microchannel plates, microchannel-plate photomultipliers, channeltrons, silicon diodes, fast photomultiplier tubes, and electron multipliers. It is particularly suited to use with the Model 9307-P pico-TIMING Discriminator to give optimum time resolution with ultra-fast detectors. Its compact case allows close coup领 to the detector to minimize sensitivity to environmental noise.

To preserve the ultra-fast rise time, the Model 9306 is designed to accept and deliver signals on high-quality, 50 W coaxial cables with SMA connectors and 50 W terminations. The input is AC coupled, with a 50 W input impedance, and is protected to a maximum of ±1 V. Two identical outputs are provided for convenient, simultaneous connection to two different instruments. Both outputs are AC coupled, short-circuit protected, and capable of driving pulse amplitudes from 0 to -2V into 50 W loads.

The preamplifier is designed for use with 50 W coaxial signal cables having SMA connectors. To avoid degradation of the 350 ps rise time through long signal cables, the total length of the input and output signal cables 首ld not exceed 1.7 m (5'). The instrument is powered via an integral 3 m (10') long power cable fitted with a 9-pin D type connector that is compatible with ORTEC NIM-standard modules and power supplies.

All specifications below were measured with a pulser having a pulse width of 2 ns FWHM, and a rise time of 150 ps. Where significant, the measurement is corrected for the rise times of the pulser, coaxial cable, and oscilloscope. The specifications are identical for both outputs 1 and 2.

产品直通车
X您尚未登录
账号登录
X您尚未登录
手机动态密码登录
X您尚未登录
扫码登录
在线留言
官方微信

仪器网微信服务号

扫码获取最新信息


仪器网官方订阅号

扫码获取最新信息

在线客服

咨询客服

在线客服
工作日:  9:00-18:00
联系客服 企业专属客服
电话客服:  400-822-6768
工作日:  9:00-18:00
订阅商机

仪采招微信公众号

采购信息一键获取海量商机轻松掌控