Cole-Parmer Four-Element Flame Photometer 02655-15
- 品牌:Cole-Parmer
- 型号:
- 产地:美国
- 供应商报价: 面议
- 科尔帕默仪器(上海)有限公司 更新时间:2024-04-23 12:47:17
-
企业性质授权代理商
入驻年限第5年
营业执照已审核
- 同类产品火焰光度计(55件)
联系方式:科尔帕默021-51099909
联系我们时请说明在仪器网(www.yiqi.com)上看到的!
-
为您推荐
- 详细介绍
- Provide accurate sodium, potassium, calcium, and lithium determinations
- Features additional calcium channel and lithium internal standard
规格与描述
- 量程ppm: all 1.00 to 9.99 ppm, 10.0 to 199.9; mmol/L: as above except Li only 1.00 to 5.00
- 特异性<0.5% interference when concentrations are equal to test sample concentrations
- 灵敏度Na & K = 0.5 ppm, Li = 2 ppm, Ca = 5 ppm
- 线性度Less than 1% at midpoint with 3 ppm K set at 100
- 可重复性Less than 0.5% CV
- 读数稳定性Variable software command
- 吸入率3 to 6 mL/min
- 气源6 L/min at 15 psi; oil and moisture free
- 显示3.5-digit LED; 12.5 mm (1/2") H
- 燃料供应High-grade propane/butane, or propane/butane mixture regulated at approximately 30 psi; natural gas - only with single-channel photometer
- 记录仪输出Two outputs: 50 mV to 7.5 V via software command
- 高度 (in)20
- 深度 (in)13 1/2
- 宽度 (in)15
- 高度 (cm)51
- 深度 (cm)34.5
- 宽度 (cm)39
- 功率 (VAC)120 / 240
- 功率 (Hz)50/60
- 描述Four-Element Flame Photometer 02655-15
包括
one each of Na+, K+, Ca+, Li+ filters, one each of 1000 ppm Na+, Ca+, K+, Li+ standards in a 100-mL bottle, two meters each of gas and air tubing with connectors, RS-2
主要特点
- Features additional calcium channel and lithium internal standard
关于该商品的更多信息
This enhanced four-element flame photometer offers the same great features found on our dual-channel flame photometer, plus a calcium channel and direct measurement of Ca+ with potassium, which are two vital elements for soil analysis. Unit allows you to measure calcium in combination with sodium, and also with lithium without an internal standard.
Use this flame photometer as a detector in combination with multi-channel analyzers from Bran & Luebbe, Skalar, and Lachat. This system includes its own protocols for calibration, and features a special mode allowing you to set up the flame photometer within these protocols. User-selectable signal averaging is designed into the system allowing you to use these protocols along with analog output. Features include automatic ignition sequence, lithium internal standard, monitoring and control software, dual-channel display, and independent calibration of each channel. An automatic gas shutoff mechanism activates if the flame is accidentally extinguished, or if air pressure drops.
Order optional Automatic Dilutor 02657-00 which accurately dilutes your samples and standards; order optional Autosampler 02657-25 for a fully automatic analysis solution for your longer sampling runs.
- Cole-Parmer 156603 Flame Photometer Calibration Standa
- Cole-Parmer Ultrasonic Twenty-Four-Element Probe; 1/8"
- Cole-Parmer Electronic Pipettor, 8 Channel; 15 to 300
- 珀金埃尔默 PinAAcle 500 Flame 原子吸收光谱仪
- Flame Ionization Detector Alkanes Test Mixture 910 0.0
- 三氟化硼甲醇溶液,15%溶于甲醇,可用于脂肪酸甲酯化
- 脂肪酸甲酯混标 GLC-428(15组分,C12-C24)
- 脂肪酸甲酯混标 GLC-484(15组分,C14-C24)
- 默克 Milli-Q IX 7003/05/10/15 实验室纯水系统