资料库
Acclaim instruction
-
本文由 赛默飞色谱质谱及痕量元素分析 整理汇编
2008-07-30 00:00 486阅读次数
文档仅可预览首页内容,请下载后查看全文信息!
-
立即下载
Acclaim instruction
登录或新用户注册
请用手机微信扫描下方二维码
快速登录或注册新账号
微信扫码,手机电脑联动
更多资料
-
Acclaim instruction
- Acclaim instruction[详细]
-
2008-07-30 00:00
其它
-
instruction of drying oven
- instruction of drying oven[详细]
-
2011-07-05 00:00
安装说明
-
Acclaim explosives manual
- Acclaim explosives manual[详细]
-
2008-07-30 00:00
产品样册
-
Acclaim surfactant manual
- Acclaim surfactant manual[详细]
-
2008-07-30 00:00
期刊论文
-
Acclaim OA manual
- Acclaim OA manual[详细]
-
2008-07-30 00:00
课件
-
Evaluation of Acclaim HPLC Columns using
- Evaluation of Acclaim HPLC Columns using[详细]
-
2008-07-30 00:00
选购指南
-
Evaluation of Acclaim HPLC Columns using the Nationa
- Evaluation of Acclaim HPLC Columns using the Nationa[详细]
-
2024-09-18 19:22
其它
-
Model MP512 Precision pH Meter Brief Operation Instruction
- Ⅰ.OperationKeys:1.ON/OFFSwitchkey2.<CAL>Calibrationkey,tomakemeterenterintocalibrationmode.3.<MODE>Functionkey(a)Short-timepress(time<1.5s)switchtheparameters,themeterwilldisplaypH-mV(b)Depress(time>2s)toenterintotheparametersettingmodeP1,andagainshort-timepresstointurndisplayP2,P3….<UNIT>Parametermodekey(a)Wheninmode,pressthekeytoalterpHresolution:0.001→0.01→0.1pH;(b)Wheninmode,pressthekeytoaltertheparametermode:→→(c)Presskeytochoosemodifiedpositionofparameterwhenintheparametersettingmode.5.<ENTER>Entrancekey,meterentersintomeasuringstateafterpressingthekey.6.<▲>and<>Increaseanddecreasekey.(a)WheninMTCstate,pressthekeytoincreaseordecreasethetemperaturevalue.(b)Wheninthestateofparametersetting,pressthekeytoalterthenumberorON/OFFstate.7.<M+/RM>Thecompoundkeyofmemoryandrecall(a)Short-timepress(time<1.5s)tosavethemeasuringinformation.(b)Depress(time>2s)torecallthemeasuringinformation,againpress<>or<▲>key,canqueryinturn.(c)Intherecal领mode,pressthe<ENTER>keytoreturntomeasuringmode.(d)Intherecal领mode,depressthe<M+/RM>keyfor5secondstoeliminatestoredinformationandreturntomeasuringmode.Statement:(a)It首ldtobecalibratedintimeforhighaccuracymeasurement(≤±0.02pH),forgenerallyaccuracymeasurement(≥±0.1pH),itcanbecontinuouslyusedforoneweekorlongertimeafteronetimecalibrating.(b)Canrandomadoptone-point,two-pointorthree-pointautomaticcalibrationaccordingtodifferentmeasuringsituations.Ⅳ.SpecialNotice:1.Whentheparametersettingisthesameastheproducersetting,therewilldisplaytimeintheupperrightcornerofLCD,whenpartsoftheparametersettingisdifferentwiththeproducersetting,therewilldisplaycodeiconintheupperrightcornerofLCD,whensettingmorethantwoparameterswithcodeicon,onlycandisplayoneofcodeicons,user首ldenterintotheparametersettinginterfacetoexaminethesetcontent,orrestorethemetertoproducersetting,thenresetthedemandparameters.2.Whenitisabnormalforcalibratingordisplaying,pleasesetthe“restoretoproducersetting”tobe“On”torestorethemetertoproducersettingstate,anddocalibrateandmeasureagain.3.Pleasedonotunplugthepowersourcewhenthemeterison,onlytounplugtheplugoftheadapterwhenthemeterispoweroff.ModelMP512PrecisionpHMeterBriefOperationInstructionⅠ.OperationKeys:1.<>Switchkey2.<CAL>Calibrationkey,tomakemeterenterintocalibrationmode.3.<MODE>Functionkey(a)Short-timepress(time<1.5s)switchtheparameters,themeterwilldisplay→(b)Depress(time>2s)toenterintotheparametersettingmodeP1,andagainshort-timepresstointurndisplayP2,P3…4.<UNIT>Parametermodekey(a)Wheninmode,pressthekeytoalterpHresolution:0.001→0.01→0.1pH;(b)Wheninmode,pressthekeytoaltertheparametermode:→→(c)Presskeytochoosemodifiedpositionofparameterwhenintheparametersettingmode.5.<ENTER>Entrancekey,meterentersintomeasuringstateafterpressingthekey.6.<▲>and<>Increaseanddecreasekey.(a)WheninMTCstate,pressthekeytoincreaseordecreasethetemperaturevalue.(b)Wheninthestateofparametersetting,pressthekeytoalterthenumberorON/OFFstate.7.<M+/RM>Thecompoundkeyofmemoryandrecall(a)Short-timepress(time<1.5s)tosavethemeasuringinformation.(b)Depress(time>2s)torecallthemeasuringinformation,againpress<>or<▲>key,canqueryinturn.(c)Intherecal领mode,pressthe<ENTER>keytoreturntomeasuringmode.(d)Intherecal领mode,depressthe<M+/RM>keyfor5secondstoeliminatestoredinformationandreturntomeasuringmode.Statement:(a)It首ldtobecalibratedintimeforhighaccuracymeasurement(≤±0.02pH),forgenerallyaccuracymeasurement(≥±0.1pH),itcanbecontinuouslyusedforoneweekorlongertimeafteronetimecalibrating.(b)Canrandomadoptone-point,two-pointorthree-pointautomaticcalibrationaccordingtodifferentmeasuringsituations.Ⅳ.SpecialNotice:1.Whentheparametersettingisthesameastheproducersetting,therewilldisplaytimeintheupperrightcornerofLCD,whenpartsoftheparametersettingisdifferentwiththeproducersetting,therewilldisplaycodeiconintheupperrightcornerofLCD,whensettingmorethantwoparameterswithcodeicon,onlycandisplayoneofcodeicons,user首ldenterintotheparametersettinginterfacetoexaminethesetcontent,orrestorethemetertoproducersetting,thenresetthedemandparameters.2.Whenitisabnormalforcalibratingordisplaying,pleasesetthe“restoretoproducersetting”tobe“On”torestorethemetertoproducersettingstate,anddocalibrateandmeasureagain.3.Pleasedonotunplugthepowersourcewhenthemeterison,onlytounplugtheplugoftheadapterwhenthemeterispoweroff.[详细]
-
2018-09-23 10:00
产品样册
-
Model MP519 Fluoride Ion Concentration Meter Brief Operation Instruction
- Ⅰ.OperationKeys:1.<ON/OFF>Switchkey2.<CAL>Calibrationkey,tomakemeterentersintocalibrationmode.3.<MODE>Functionkey(a)Short-timepress(time<1.5s)switchtheparameters,themeterwillinturndisplayISE→mV.(b)Depress(time>2s)toenterintotheparametersettingmodeP1,andagainshort-timepress,willinturndisplayP2→P3→…4.<UNIT>Unitkey(a)Wheninmode,pressthekeytointurnalterunitsymbol:pF→mol/L→mg/L→ppm;(b)Presskeytochoosemodifiedpositionofparameterwhenintheparametersettingmode.5.<ENTER>Entrancekey,meterentersintomeasuringstateafterpressingthekey.6.<▲>and<>Increaseanddecreasekey(a)WheninMTCstate,pressthekeytoincreaseordecreasethetemperaturevalue.(b)Wheninthestateofparametersetting,pressthekeytoalterthenumberorON/OFFstate.7.<M+/RM>Thecompoundkeyofmemoryandrecall(a)Short-timepress(time<1.5s)tosavethemeasuringinformation.(b)Depress(time>2s)torecallthemeasuringinformation,againpress<>or<▲>key,canqueryinturn.(c)Intherecal领mode,pressthe<ENTER>keytoreturntomeasuringmode.(d)Intherecal领mode,depressthe<M+/RM>keyfor5secondstoeliminatestoredinformationandreturntomeasuringmode.Ⅱ.FluorideIonConcentrationMeasurement:[详细]
-
2018-09-23 10:00
产品样册
-
Model MP518 Calcium Ion Concentration Meter Brief Operation Instruction
- Ⅰ.OperationKeys:Ⅱ.CalciumIonConcentrationMeasurement:Statement:(a)①isthemeasuringprocedurebyusingC1andC2calibrationsolutionaccordingtoproducersetting.(b)②isthemeasuringprocedurewhichC1andC2calibrationsolutionbeself-definedbyuser.Ⅲ.ParameterSettingSchedule:Ⅳ.SpecialNotice:1.Whendoingcalciumionconcentrationmeasuring,generallyrequeststodocalibration;2.Whendoingcalciumionconcentrationmeasuring,thetemperatureforcalibrationsolutionandsamplesolution首ldbeequalorclose;3.Whenitisabnormalforcalibratingordisplaying,pleasesetthe“restoretoproducersetting”tobe“On”torestorethemetertoproducersettingstate,anddocalibrateandmeasureagain.4.Pleasedonotunplugthepowersourcewhenthemeterison,onlytounplugtheplugoftheadapterwhenthemeterispoweroff.[详细]
-
2018-09-23 10:00
产品样册
-
Nitrogen Evaporation System Models 111, 112, 115 INSTRUCTION MANUAL
- Nitrogen Evaporation System Models 111, 112, 115 INSTRUCTION MANUAL[详细]
-
2024-09-20 13:27
产品样册
-
Nitrogen Evaporation System Model 118 DIGITAL & TIME CONTROL SYSTEM INSTRUCTION MANUAL
- Nitrogen Evaporation System Model 118 DIGITAL & TIME CONTROL SYSTEM INSTRUCTION MANUAL[详细]
-
2013-04-16 00:00
操作手册
-
Solvent Evaporation System Model 120 Nitrogen Injection Option Vacuum Assist Option INSTRUCTION MANUAL
- Solvent Evaporation System Model 120 Nitrogen Injection Option Vacuum Assist Option INSTRUCTION MANUAL[详细]
-
2013-04-16 00:00
安装说明
-
AN195 Acclaim PA柱检测盐酸维拉帕米纯度.pdf
- AN195 Acclaim PA柱检测盐酸维拉帕米纯度.pdf[详细]
-
2009-04-28 00:00
安装说明
-
AN198 用Acclaim混合基质HILIC柱分析美容产品中的尿素和
- AN198 用Acclaim混合基质HILIC柱分析美容产品中的尿素和[详细]
-
2009-04-28 00:00
应用文章
-
Acclaim C30 色谱柱分析养正消积胶囊中的齐墩果酸
- Acclaim C30 色谱柱分析养正消积胶囊中的齐墩果酸[详细]
-
2024-09-28 01:25
应用文章
-
赛默飞Acclaim C30 色谱柱分析养正消积胶囊中的齐墩果酸
- 赛默飞Acclaim C30 色谱柱分析养正消积胶囊中的齐墩果酸[详细]
-
2024-09-29 13:15
应用文章
-
Acclaim Mixed-Mode 系列色谱柱应用于益母草颗粒、 益母草膏中盐酸水苏碱和盐酸益母草碱含量的测定
- 本文采用 Acclaim Mixed-Mode WAX-1 色谱柱配合 CAD 检测器,测定益母草颗粒、益母草膏中盐酸水苏碱的含量,以乙腈-甲酸铵溶液为流动相进行梯度洗脱,在 HILIC 和 WAX 双重作用机理下,增强了对盐酸水苏碱的保留能力,可有效与供试品溶液中的杂质峰分离。同时,采用 Acclaim Mixed-Mode WCX-1色谱柱配合 DAD 检测器,测定益母草颗粒、益母草膏中盐酸益母草碱的含量,以乙腈-甲酸铵溶液为流动相进行等度洗脱,在RP 和 WCX 双重作用机理下,增强了对盐酸益母草碱的保留能力,可有效与供试品溶液中的杂质峰分离。在两种不同的分析方法下,盐酸水苏碱和盐酸益母草碱的峰形优异,柱效卓越,避免了复杂基质的干扰,可实现准确的定性和定量,助力益母草相关品种的标准提高。[详细]
-
2024-09-14 23:19
应用文章
-
AN_24059_CCS_药物_Acclaim C30 色谱柱配合 Vanquish Core 液相色谱系统应用于尿苷、假尿苷和 N1-甲基假尿苷的分离
- 在 mRNA 疫苗的生产过程中,N1- 甲基假尿苷 (m1Ψ) 作为一种化学修饰核苷,常用来降低外源合成 mRNA 的免疫原性,提升抗原翻译效率。[详细]
-
2025-08-12 15:24
产品样册
-
AN_23044_CCS_药物_Acclaim Mixed-Mode 系列色谱柱应用于益母草颗粒、益母草膏中盐酸水苏碱和盐酸益母草碱含量的测定
- 在两种不同的分析方法下,盐酸水苏碱和盐酸益母草碱的峰形优异,柱效卓越,避免了复杂基质的干扰,可实现准确的定性和定量,助力益母草相关品种的标准提高。[详细]
-
2025-08-12 13:45
产品样册
Copyright 2004-2026 yiqi.com All Rights Reserved , 未经书面授权 , 页面内容不得以任何形式进行复制
参与评论
登录后参与评论