仪器网(yiqi.com)欢迎您!

| 注册2 登录
网站首页-资讯-专题- 微头条-话题-产品- 品牌库-搜索-供应商- 展会-招标-采购- 社区-知识-技术-资料库-方案-产品库- 视频

产品中心

仪器网>产品中心> 深圳市达瑞博电子有限公司>其他仪器仪表>96040A Low Phase Noise Reference Source ZL

96040A Low Phase Noise Reference Source ZL

面议 (具体成交价以合同协议为准)
美国福禄克 美洲 美国 2026-01-09 09:36:06
售全国 入驻:7年 等级:银牌 营业执照已审核
扫    码    分   享

立即扫码咨询

18938937317

已通过仪器网认证,请放心拨打!

联系我们时请说明在仪器网(www.yiqi.com)上看到的,谢谢!

为你推荐

产品特点:

The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system

产品详情:

公司介绍图片.png


  深圳市达瑞博电子有限公司长期出售及租赁进口二手仪器仪表:网络分析仪、频谱分析仪、信号发生器、示波器、天馈线测试仪、多功能校准器/传感器模块、手机综合测试仪、噪声系数分析仪、NI-GPIB卡、阻抗/LCR测试仪、音频分析仪、蓝牙测试仪、功率计、放大器、万用表等各类仪器仪表。

 

   经营品牌:安捷伦Agilent(Keysight)、R&S罗德与施瓦茨、Tektronix泰克、Anritsu安立、SPIRENT思博伦、Giga-tronics、Advantest爱德万、Aeroflex艾法斯、IFR、韩国兴仓PROTEK、JDSU真康、FUJITSU 富士通、SUNGSAN、TESCOM泰仕康、Keithley吉时利、Fluke福禄克、LitePoint莱特波特等。
 联系电话:
 张  梁:18938937317  
 廖先生:13421364554

 产品介绍图片.png

 

96040A Low Phase Noise Reference Source

96040A Low Phase Noise Reference Source
96040A Low Phase Noise Reference Source
 
96040A Low Phase Noise Reference Source
 
96040A Low Phase Noise Reference Source
 
96040A Low Phase Noise Reference Source
  • 概述

  • 产品综述

  • 技术指标

  • 型号和配件

  • 相关文档

 Simplify your RF calibration system

The Fluke Calibration 96040A RF Reference Source enables you to simplify your RF calibration system by replacing many of the instruments and accessories that make up your current system. Its precision signal level and attenuation, high signal purity and precision low distortion modulation make this reference source superior to the general-purpose signal generators that are often used to calibrate spectrum analyzers, modulation meters, RF sensors, attenuators, and similar instruments. Its low phase noise provides superior phase noise performance.

Unlike many RF calibration solutions, the 96040A is designed specifically for RF calibration, with a calibration-oriented user interface that makes it easy to learn and use. The 96040A speeds up calibration procedures, reduces opportunities for operator errors, and greatly simplifies RF metrology. As the core of an RF and microwave calibration system, the 96040A covers the majority of test points required for calibrating spectrum analyzers of any frequency range.

Automated with MET/CAL® Plus Calibration Management Software, the 96040A reduces complexity and calibration times, dramatically improving efficiency and increasing capacity by 50 % or more over manual methods.

Key benefits

  • Covers a broad range of RF calibration workload

  • Reduces the number of instruments and interconnections required for your RF calibration system

  • “What you set is what you get” accurate signal delivery direct to the DUT input

  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks

  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)

  • Lowers RF system maintenance costs

  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods

Broad, versatile workload coverage

The 96040A calibrates a broad workload of RF calibration devices, including:

• Spectrum analyzers

• Modulation meters and analyzers

• RF power meters and sensors

• Frequency counters

• Attenuators

• And more

The metrology associated with calibrating these items becomes simpler because you have fewer error sources and uncertainty contributions to consider.

More than just an RF calibrator

There are many applications in research and development, manufacturing test, and ATE needing better performance than a general purpose signal generator. If wide frequency coverage, frequency resolution, low harmonics, phase noise and spurious content, signal level and attenuation accuracy, or dynamic range are critical parameters the 96040A is an ideal solution.

Cut the cost of your RF calibration system in half

As the central instrument in a high capability RF spectrum analyzer calibration system, the 96040A can cut your costs in half. The 96040A replaces all of these parts of a “typical” RF calibration system:

Up to four signal sources (from audio/ function generators to RF signal and low phase noise sources)

  • Power meters and power sensors

  • Step attenuators

  • Filters

  • Pads

  • Couplers

  • 50 MHz frequency counter

The 96040A not only reduces the initial need to purchase, install and configure RF system components, but it also reduces the maintenance and calibration costs associated with all of that equipment. The 96040A is also easier to transport than a heavy rack of equipment and accessories, making it a good solution for on-site calibration.

With its 4 GHz frequency range, the 96040A performs more than 80 % of all the tests required on high performance, high frequency spectrum analyzers.

For workload items that require frequencies beyond 4 GHz, you can use an RF and microwave source that you probably already own alongside the 96040A to address the few remaining higher frequency test points. For many spectrum analyzer models operating below 4 GHz, you only need a 96040A to perform the entire calibration. You can’t simplify much more than that!

No need for additional function generators

The 9640A Reference Source’s internal modulation capability makes it suitable for applications that require precision modulation to be applied to the output signal, such as modulation analyzer calibration and spectrum analyzer sweep time testing using an AM signal with more accurate modulation rates. You don’t need additional function generators as a low frequency modulation source—the 96040A delivers it all.

Designed for RF calibration

The 96040A user interface is designed to simplify processes for calibrating typical items in your workload, such as spectrum analyzers, RF level meters and receivers. Parameter offset, stepping, relative and DUT error readout modes allow you to work accurately and efficiently, following familiar calibration procedures. You’ll find it easier than ever to determine the performance and tolerances of units under test.

The 96040A front panel is equipped with dedicated function keys, context-sensitive softkeys, and a bright, easy-to-read color display that make it easy to learn and operate. You can set output levels in terms of power (watts or dBm), voltage (RMS or peak to peak) using familiar multipliers and exponent forms. You can move easily between voltage, power and dBm units without losing entered values or accuracy. In error readout mode to adjust the reading, simply rotate the spin wheel and the DUT error is displayed directly in dB, ppm or percent.

The simple, calibration-oriented user interface also makes troubleshooting easier if you encounter an unexpected result or an out-of-tolerance condition while following a manual or automated calibration procedure.

“What you set is what you get” accuracy and signal purity

A rugged, precise levelling head delivers 96040A signal levels directly to the device under test (DUT) input just the way you set them on the front panel. This unique “What you set is what you get” feature helps you avoid problems like losses, noise, interference, and mismatch errors, which can be caused by using intermediate connectors and cables. This approach also maintains the integrity of low-level signals. The head maintains signal precision and noise immunity throughout a 154 dB dynamic range, down to the very lowest levels at -130 dBm.

The leveling head reduces lead changes from 25 to just 5 during a typical calibration, allowing you to “connect once and test many,” extending unattended times in an automated system, and reducing connector wear.

Calibrated as a system to assure system performance

The 96040A is supplied with a 50 ohm leveling head. The /75 model has both 50 ohm and 75 ohm leveling heads. Each mainframe and head are calibrated together as a complete system. System calibration helps assure overall system performance. Each 96040A instrument is supplied with a comprehensive ISO 17025 compliant certificate of calibration with data for all key parameters, including level and attenuation, output VSWR, and phase noise. You can be assured that your 96040A is traceable, plus RF metrology and uncertainty analysis become much simpler and faster. Accredited certification is available for the 96040A and both 50 ohm and 75 ohm heads.

State-of-the-art phase noise performance

With reduced low phase noise optimized for low and high offset frequencies and specifications from 1 Hz to 10 MHz offsets, the 96040A offers exceptional phase noise performance beyond that required for today’s high performance workloads.

Phase noise data is included in the 96040A certificate of calibration. Instead of relying only on the more conservative guaranteed specifications, users have actual performance data for their unit. Even with the best low phase noise signal generators, filters are commonly used during spectrum analyzer phase noise calibration tests, reducing noise levels at wide (high) offset frequencies to improve test margins. The 9600FLT 1 GHz bandpass filter accessory is designed specifically for high performance spectrum analyzer wide-offset phase noise testing and connects easily to 96040A models in either benchtop or rack-mounted applications.

Selectable frequency reference input/ output expands functionality

Selectable external frequency reference input is available as a standard feature on the rear panel of the 96040A. The input allows you to lock the frequency output to an external reference, such as the Fluke Calibration 910R Rubidium Standard, for applications where high clock accuracy or use of a common reference frequency is important. The frequency reference output allows a DUT to be frequency locked to the 96040A internal reference clock. This configuration is often required to reduce frequency offset errors that may occur between the reference source and the DUT.

Simplify frequency response tests with 96040A sweep functions

RF applications often require a frequency sweep. The 96040A’s sweep functions simplify the application of manual legacy spectrum analyzer frequency response testing, as well as filter response measurements.

Automate with MET/CAL® software for “walk-away” efficiency

In a typical automated RF calibration process, the operator must frequently intervene to change test setups, thus limiting the benefits that can be realized by the automation. Walk-away automation can increase calibration system capacity by up to 25 percent using procedures you develop in MET/CAL  Calibration Management Software. For example, the manufacturer’s calibration procedure for calibrating the Agilent E4407B 26.5 GHz spectrum analyzer requires 27 different and complex test setups. On the other hand, the 96040A, used with MET/CAL  Calibration Management Software, can perform the major core of required tests with a single setup. Only six additional setups would be needed using a MET/CAL procedure.

MET/CAL procedures created by Fluke Calibration for the 9640A models can be used by the 96040A in 9640A emulation mode. Optimized automated procedures can save time for the operators by allowing them to leave the system running while attending to other work. For example, the E4407B MET/CAL procedure for the legacy 9640A, running in emulation mode on the 96040A, allows for a total 90 minutes of “walkaway” time within the total two-hour calibration runtime.

Using the 96040A with other automation solutions

The 96040A is also integrated easily into existing automated systems and software. The time savings and efficiency gains offered by the 96040A can be realized by structuring test sequences to take full advantage of its “connect once measure many” capabilities.

The 96040A is designed to match or exceed the performance and functionality of the HP3335A and HP8662/3A in calibration systems. With HP3335A and HP8662/3A GPIB command emulation as standard, replacing these popular but obsolete and difficult-to-maintain products becomes just a plug-and-play substitution.

 

温馨提示:

     本产品上标的价格只是参考价格,因为市场价格影响波动大,所以价格也会有影响,具体价格还请联系客服,请勿直接下单,谢谢合作!

 

   如有需要,欢迎随时联系我们,谢谢!

  


 

 

 

 

 

 

 


您可能感兴趣的产品

深圳市达瑞博电子有限公司为你提供96040A Low Phase Noise Reference Source ZL信息大全,包括96040A Low Phase Noise Reference Source ZL价格、型号、参数、图片等信息;如想了解更多产品相关详情,烦请致电详谈或在线留言!
  • 相关品类
  • 同厂商产品

您可能还在找

新品推荐

FPL 频谱分析仪 ZL

主要特点 频率范围介于 5 kHz 至 26.5 GHz SSB 相位噪声:10 kHz 偏置时典型值为 –108 dBc (1 Hz) 使用前置放大器时的 DANL:10 MHz 至 2 GHz

R&S®ZN-Z3x 内联校准单元 ZL

一键进行校准更新 适用于 TVAC 系统、生产、多端口系统 频率最高 8.5 GHz 和 40 GHz,TVAC 型号频率最高 40 GHz CAN 总线控制,一个 R&S®ZN-Z30 控制器支持至

罗德与施瓦茨ZN-Z15x 网络分析仪校准单元 ZL

自动校准单元具备 2、4 或 6 个端口,8.5 GHz R&S®ZN-Z154 多端口校准单元可配置至多 24 个端口 轻松校准具有至多 24 个端口的多端口装置,无需多次进行重新连接 R&S®ZN

罗德与施瓦茨ZV-Z5x 网络分析仪多端口校准单元 ZLR&S®ZV-Z5x

主要特点 高端自动校准单元 主要用于 R&S®ZVA 高端矢量网络分析仪系列 多端口校准单元,适用于 R&S®ZVT8 和 R&S®ZVT20 多端口网络分析仪

R&S®ZN-Z5x 自动校准单元 ZL

主要特点 9 kHz 至 50 GHz 的宽频率范围 几乎无需预热 自动检测和 USB 控制 支持多端口校准

R&S®ZN-Z1xx 经济型网络分析仪校准套件 ZL

主要特点 开路器、短路器、匹配负载和直通组合在紧凑单元中 独立的阳性或阴性套件型号 可用于 N 型、3.5 mm、2.92 mm 连接器 2.92 mm“E”型号的频率高达 43.5 GHz 提供阳

DSOV254A Infiniium V 系列示波器 ZL

25 GHz 模拟带宽(可升级) 4 个模拟通道 高达 80 GSa/s 的采样率和 2 Gpts 采集存储器可以捕获更长时间的信号迹线 低本底噪声(在 50 mV/格时为 1.73 mVrms)和测

MXR108B Infiniium MXR B 系列示波器 ZL

全部 8 个通道均可提供 1 GHz 带宽;可通过选件构成强大的 8 合 1 仪器;具有出色的硬件加速绘图功能;可以全面升级到 6 GHz 带宽

推荐品牌

美国福禄克 美国爱光 美国安博 美国Orion 美国哈希 美国MTS 美国TSI 美国海洋光学 美国华瑞 美国德威尔