Rxi-PAH Columns(fused silica)



(midpolarity proprietary phase)

  • Ideal for EFSA PAH4 analysisseparates all priority compounds: benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene.
  • Best resolution of chrysene from interfering PAHs, triphenylene, and cyclopenta[cd]pyrene.
  • Complete separation of benzo [b], [k], [ j], and [a] fluoranthenes.
  • 360 °C thermal stability allows analysis of low volatility dibenzo pyrenes.
  • The Rxi-PAH GC columns were designed by Restek with a higher phenyl-content stationary phase that provides unique selectivity to separate important polycyclic aromatic hydrocarbons (PAH) for food safety that cannot be distinguished by mass spectrometry. Even difficult priority compounds, such as the European Food Safety Authority (EFSA) PAH4, are easily separated and accurately quantified, results that cannot be achieved on typical GC columns. Arylene modification and surface bonding of the stationary phase increase thermal stability and ruggedness so relatively nonvolatile, higher molecular weight PAHs can be analyzed routinely without interference from column bleed. Excellent column efficiency means that the column can be trimmed for maintenance purposes many times without losing critical PAH separations, including those that are part of environmental methods, as well as food safety testing. The selectivity and efficiency of the Rxi-PAH column make it ideal for EFSA PAH4 analysis; chrysene/triphenylene separation and resolution of all benzofluoranthenes are easily achieved.



    cat.# Description

    49316 Narrow inside diameter, thinner film, faster analysis, excellent separation of important PAHs, less sample loading capacity

    49317 0.25 mm inner diameter, better sample loading capacity, highest resolution of important PAHs, longer analysis than 0.18 mm column, thin film allows elution of dibenzo pyrenes

    49318 0.25 mm inside diameter, better sample loading capacity, faster analysis time than 60 m column, adequate resolution of important PAHs, lower cost column



订货信息:
49316 Rxi-PAH Cap. Column 40m, 0.18mm ID, 0.07um
49317 Rxi-PAH Cap. Column 60m, 0.25mm ID, 0.10um
49318 Rxi-PAH Cap. Column 30m, 0.25mm ID, 0.10um