上海湘润介绍西门子SIPROCESS UV600紫外线分析仪
- 上传人: 上海湘乾仪器仪表有限公司 |大小:476.65KB|浏览:521次|时间:2018-09-28
- 文档简介
- 您可能感兴趣的资料
-
更多详细的资料请来电咨询,我们将为你提供**的服务,我司是全国**总代里西门子分析仪,也是**的一家能做到价
-
崂应3023型 紫外差分烟气综合分析仪是以紫外差分吸收光谱分析技术(DOAS)为核心的新型产品,主要用于固定
-
从分析精度上来说,流动注射仪相比以前用的老方法,降低了检出限,以前挥发酚的检出限是0.004mg/l,对于地
-
高速碳硫分析仪 高速碳硫分析仪是分析钢铁中碳、硫元素含量的重要仪器,而燃烧法测定碳硫时添加剂的选用是一个值
-
Olympus土壤重金属分析仪手册
-
Olympus土壤重金属分析仪
-
Olympus土壤重金属分析仪手册
-
Futura连续流动分析仪
-
SmartChem间断化学分析仪
-
SmartChem200间断化学分析仪
ContinuousGasAnalyzers,extractive西门子SIPROCESSUV600紫外线分析仪2/1SiemensPA01NewsFebruary20122■OverviewThefunctionoftheSIPROCESSUV600gasanalyzerisbasedonUVresonanceabsorptionspectrometry.ItalsoisusedtomeasureverylowNO,NO2,SO2orH2Sconcentrationsingases.■BenefitsVerylowcross-sensitivitywithothergasesAllmodulesarethermostatically-controlled,andthusindependentoftheambienttemperatureSimultaneousmeasurementofNOandNO2withsubsequentcalculationoftotal.ThereforeneitheranNO2converternoraCLDanalyzerisrequired.MeasurementintheUVrange:-Nocross-sensitivitywithH2OandCO2-VerylowSO2andNOmeasuringrangespossibleUVresonanceabsorptionspectrometry:-MeasurementofverylowNOconcentrations-Verylowcross-sensitivitypossibleVerylongservicelifeofUVlamp(usually2years)Lowdriftsandhighstabilitythankstofour-channelmeasuringmethodwithdoublegenerationofquotientTruereferencemeasurementforlow-drift,stableresultsInterfaceforremotemonitoringinnetworksandlinkingtoprocesscontrolsystemsOptionalcalibrationunit-Filterwheelwithcalibrationcellswhichcanbeautomaticallyswungintotheopticalpath-Lowconsumptionofcalibrationgas-Manualorautomaticcalibrationpossible■ApplicationFieldsofapplicationEmissionmeasurements-MeasurementoflowNOconcentrationsinpowerplantsorgasturbines-MonitoringofNOxindenitrificationplantsbydirectmeasurementofNOandNO2,aswellassummationtoNOxintheanalyzer-Efficientmeasurementindesulfurizationplants-MonitoringofverysmallSO2andNOconcentrations-Emissionmeasurementsinthepaperandcelluloseindus-triesProcessmonitoring-MeasurementofSO2inprocessgasesinthepaperandpetrochemicalindustries-OptimizationofNOxemissionsinexhaustgasintheautomotiveindustry-H2SandSO2measurementsintheresidualgaspurificationofsulfurrecoveryunitsSpecialversionsSpecialapplicationsInadditiontothestandardcombinations,specialapplicationsarealsoavailableuponrequest,e.g.asregardsthematerialinthegaspathandthesamplechambers.SiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/2SiemensPA01NewsFebruary20122西门子SIPROCESSUV600紫外线分析仪标准气体测量NOZ小测量范围0…10ppmv0…20ppmv0…25ppmv0…50ppmvZda测量范围0...300ppmv0...400ppmv0...500ppmv0...1000ppmvNO2Z小测量范围0…10ppmv1)0…20ppmv0…25ppmv0…50ppmvZda测量范围0...300ppmv0...400ppmv0...500ppmv0...1000ppmvSO2Z小测量范围0…10ppmv1)0…20ppmv0…25ppmv0…50ppmvZda测量范围0...300ppmv0...400ppmv0...500ppmv0...1000ppmvH2SZ小测量范围0…25ppmv0…50ppmvZda测量范围0...500ppmv0...1000ppmv■Design19"rackunitwith4HUforinstallation-inhingedframe-incabinetswithorwithouttelescopicrailsInternalgaspaths:hosemadeofFKM(VitonTM)orpipemadeofPTFEorstainlesssteelGasconnectionsforsamplegasinletandoutletandforreferencegas:fittings,pipediameterof6mmor"DisplayandcontrolpanelLargeLCDpanelforsimultaneousdisplayofmeasuredvalueanddevicestatusSensorbuttonswithcontext-basedfunctionsDisplayprotectedbyglasspaneContrastoftheLCdisplaycanbeadjustedSIPROCESSUV600,displayandcontrolpanelInputsandoutputs2configurableanaloginputs4configurableanalogoutputs8digitalinputs8digitaloutputsCommunicationsConnectionviaSIPROCESS-UV600-specificsoftwaretoolMaterialswettedbysamplegas1)DependingontheversionGasflowchartSIPROCESSUV600,gasflowchartComponentMaterialAnalyzerunit(samplechamber)Aluminumorstainlesssteelmat.no.1.44041),epoxyresinOpticalwindowCaF2orquartz1),epoxyresinGaspath,gasketsFKM(Viton),PTFE,stainlesssteelmat.no.1.45711)ChamberAluminumorstainlesssteel1)Gasinlet/outletPVDF,stainlesssteel,mat.no.1.44011)MoisturesensorStainlesssteelmat.no.1.4571,platinum,epoxyresinDiaphragmpumpCentralbodyPVDFDiaphragmFKM(Viton),EPDMoSamplegasinletSamplegasoutletMoisturesensor(optional)Filter(optional)UVmoduleSiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/3SiemensPA01NewsFebruary20122■ModeofoperationThemeasuringprincipleoftheSIPROCESSUV600isbasedonthemolecule-specificabsorptionofgasesintheultravioletwavelengthrange.Radiationofawavelengthappropriatetothemeasurementispassedthroughthesample,andtheselectiveabsorptionwhichisproportionaltotheconcentrationofthemeasuredcomponentisdetermined.MeasuringmethodAnelectrodelessdischargelamp(1)emitsbroadbandintheultravioletspectralrange.Afilterwheelunit(2)generatestheultravioletradiationsuitablefortherespectivemeasuredcomponent.Eitherinterferencefiltercorrelation(IFC)orgasfiltercorrelation(GFC),oracombinationofthetwomethods,canbeusedforthispurpose.Interferencefiltercorrelation(IFC)Thesampleandreferenceradiationsaregeneratedalternatelywithtwodifferentinterferencefiltersbeingswungintothebeampath(filterwheel2a).Gasfiltercorrelation(GFC)EspeciallywhenNOisthemeasuredcomponent,thereferenceradiationisgeneratedbyswinginginagasfilterwhichisfilledwiththeassociatedgas(filterwheel2b).IFCandGFCThetwofilterwheelsarecombinedinordertomeasureNOincombinationwithothermeasuredcomponents.DesignoftheanalyzerunitAfterpassingthroughthefilterunit,thebeamisdirectedviaalens(3),abeamdivider(4)andamirror(4)intothesamplechamber(6)andreferencechamber(7).Thesamplebeampassesthroughthesamplechamber(6),intowhichsamplegasflows,anditsintensityisweakenedinlinewiththeconcentrationofthemeasuredcomponent.Thereferencebeamisdirectedviaamirror(5)intothereferencechamber(7).Thisisfilledwithaneutralgas.Thedetectors(9)receivethesampleandreferencebeamsinsuccession.Thesemeasuredsignalsareamplifiedandevaluatedusingelectronics.Themeasuringsystemistemperature-controlledtominimizeexternaltemperatureinfluences.Thephysicalstateofthemeasuringsystemisrecordedsimulta-neouslythroughtime-offsetdetectionofthereferencebeam,andcompensatedifnecessary.Aquotientisgeneratedforeachdetectorfromthedeterminedsignalvalues,andtheratioofthesequotientsdetermined.Thisdoublegenerationofquotientsmeansthatsymmetricalsignaldriftsarecompensatedinthebestpossiblemannerinadditiontoproportionalsignaldrifts.NoteThesamplegasesmustbefedintotheanalyzersfreeofdust.Condensationinthesamplechambersmustbeprevented.Therefore,theuseofgasmodifiedforthemeasuringtaskisnecessaryinmostapplicationcases.SiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/4SiemensPA01NewsFebruary20122■FunctionSIPROCESSUV600,operatingprinciple9M2aIFCGFC2bMIFC+GFCMM2b2aM101235492a2b6788MM1UVlamp2Filterwheelunit2aFilterwheel12bFilterwheel23Collimatorlens4BeamdividerGFCGasfiltercorrelationIFCInterferencefiltercorrelationMMotor5Mirror7Referencechamber8Focuslens9Detector10CalibrationunitSiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/5SiemensPA01NewsFebruary20122■Technicalspecifications1)Onlyfordailyrecalibrationandair-conditionedenvironment(+/-2°C)GeneralinformationMeasuringranges3,automaticmeasuringrangeswitchingDetectionlimit(2σ)<1%ofspanSmallestpossiblespanDependentonorderconfigurationNO:0...10/0…20/0…25/0…50vpmNO2:0…101)/0...20/0…25/0…50vpmSO2:0…101)/0...20/0…25/0…50vpmH2S:0…25/0…50vpmLargestpossiblespanDependentonorderconfigurationNO,NO2,SO2:0…300to0...1000vpmH2S:0…500to0...1000vpmUVlampDesignEDL,electrodelessdischargelampServicelife≈2years(17500h)ConformityCEmarkDesign,enclosureDegreeofprotectionIP40Weightapprox.17kgRequirementsoflocationofuseInstallationlocationWithinclosedbuildingAtmosphericpressureintheenvironment700…1200hPaRelativehumidity10...95%,non-condensingPermissiblecontaminationPollutiondegree1Maximumgeographicaltitudeoflocationofuse2500mabovesealevelPermissibleambienttemperatureOperation+5...+45°C(41...113°F)Transportandstorage-10...+70°C(14...158°F)OperatingpositionFrontwall,vertical,max.±15°angleforeachspatialaxis(maximumpermissibleinclinationofthebasesurfaceduringoperationwtihconstantoperatingposition)Permissiblevibration/shockVibrationdisplacement0.035mm(intherange5...59Hz)Amplitudeofthestartingacceler-ation5m/s2(intherange59…160Hz)ElectricalcharacteristicsLinevoltage(optional,seenameplate)93...132VAC,186...264VACLinefrequency(AC)47...63HzPermissibleovervoltages(transientsurgesinthepowersupplynetwork)UptoovervoltagecategoryIIinaccordancewithIEC60364-4-443PowerconsumptionApprox.50VA,max.300VAEMCinterferenceimmunity(electro-magneticcompatibility)InaccordancewithEN61326-1,EN61326-2-1,EN61000-6-2,EN61000-6-4andEUDirective2004/108/EC.Inthecaseofelectro-magneticradiationinthefrequencyrangefrom750MHz±20MHz,increasedmeasuringerrorscanoccurforsmallmeasuringrangesElectricalsafetyInaccordancewithEN61010-1Internallinefusesprimary6.3A,notreplaceablesecondary8AGasinletconditionsPermissiblesamplegaspressureRelativetoambient/atmosphericairpressure:-200...+300hPa(-0.2...+0.3bar)Samplegasflow20...120l/h(333...2000ml/min)Samplegastemperature5...55°CMeasuringresponse(relatingtosamplegaspressure1013hPaabsolute,0.5l/minsamplegasflowand25°Cambienttemperature)Referencepointdrift<±1%/weekofrespectivespanZeropointdriftStandardmeasuringranges<±1%/weekofrespectivespanSmallmeasuringranges(≤2xsmallestmeasuringrange)<±2%/weekofrespectivespanMeasuredcomponentsNO,NO2,SO2<±1%/dayofrespectivespanRepeatability(reproducibility)<±1%ofrespectivespanLinearityerror<±1%ofrespectivespanElectricinputsandoutputsAnalogoutput4,0...24mA;floating(electricallyisolated),residualripple0.02mA,resolution0.1%(20μA),max.load500Ω,max.voltage±50VRelayoutputs8,withchangeovercontacts,max.voltage±50Vloadingcapacity:Max.30VAC/max.48VDC/max.500mAAnaloginputs2,0...20mA,referencepotentialGND,signalstrengthmax.30mA,overcurrentprotectionmax.±1A,voltagemax.±50VDigitalinputs8,switchingrange14...42V(externalcontrolvoltage),max.voltage±50VSerialinterfaceRS485,Ethernet(LAN)SiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/6SiemensPA01NewsFebruary20122■SelectionandorderingdataProductdescriptionOrderNo.SIPROCESSUV600gasanalyzer,incl.gasmoduleandbarometricpressurecompensation7MB2621-77777-0777CannotbecombinedEnclosure,versionandgaspaths19"rackunitforinstallationincabinetsGasconnec-tionsGasconnectionsGaspathsDiameterMaterialMaterial6mmpipePVDFHose/Viton06mmpipeSwagelokPTFE16mmpipeSwagelokStainlesssteel,withpipes21/4"pipeSwagelokStainlesssteel,withpipes31.UVmeasuredcomponentMeasuredcomponentSmallest/largestmeasuringrangecorrespondstoNO0...10/0...300ppmv0…15/0...450mg/m3AA0...20/0...400ppmv0…25/0...500mg/m3AB0...25/0...500ppmv0…35/0…700mg/m3AC0...50/0...1000ppmv0…50/0...1000mg/m3ADNO20...10/0...300ppmv1)0…20/0…600mg/m31)BABA0...20/0...400ppmv0…40/0…800mg/m3BBBB0...25/0...500ppmv0…50/0…1000mg/m3BCBC0...50/0...1000ppmv0…100/0...2000mg/m3BDBDSO20...10/0...300ppmv1)0…25/0…750mg/m31)CACA0...20/0...400ppmv0…50/0…1000mg/m3CBCB0...25/0...500ppmv0…75/0…1500mg/m3CCCC0...50/0...1000ppmv0…130/0…2600mg/m3CDCDH2S0...25/0...500ppmv0…40/0…800mg/m3DCDC0...50/0...1000ppmv0…75/0...1500mg/m3DDDD2.UVmeasuredcomponentMeasuredcomponentSmallest/largestmeasuringrangecorrespondstowithout0000NO20...10/0...300ppmv1)0…20/0…600mg/m31)21210...20/0...400ppmv0…40/0…800mg/m322220...25/0...500ppmv0…50/0…1000mg/m323230...50/0...1000ppmv0…100/0...2000mg/m32424SO20...10/0...300ppmv1)0…25/0…750mg/m31)31310...20/0...400ppmv0…50/0…1000mg/m332320...25/0...500ppmv0…75/0…1500mg/m333330...50/0...1000ppmv0…130/0…2600mg/m33434H2S0...25/0...500ppmv0…40/0…800mg/m343430...50/0...1000ppmv0…75/0...1500mg/m344443.UVmeasuredcomponentMeasuredcomponentSmallest/largestmeasuringrangecorrespondstowithoutXXSO20...10/0...300ppmv1)0…25/0…750mg/m31)CACACA0...20/0...400ppmv0…50/0…1000mg/m3CBCBCB0...25/0...500ppmv0…75/0…1500mg/m3CCCCCC0...50/0...1000ppmv0…130/0…2600mg/m3CDCDCDH2S0...25/0...500ppmv0…40/0…800mg/m3DCDCDC0...50/0...1000ppmv0…75/0...1500mg/m3DDDDDD1)Smallestmeasuringrange0...10ppmonlyinthecaseofdailyrecalibrationandair-conditionedenvironment(±2°C)SiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/7SiemensPA01NewsFebruary2012■Selectionandorderingdata(continued)2PowercableEUstandard,straight0UKstandard1USstandard2AdditionalversionsPleaseadd"-Z"totheordernumberandspecifytheordercode.SecondIOmoduleA13Calibrationunit1componentB11Calibrationunit2componentsB12Calibrationunit3componentsB13FlowmonitorC11HumiditymonitorC12Pressuresensor(samplegas)C14DescriptionQuantityfor2yearsQuantityfor5yearsOrderNo.SafetyfilterFI6412A5E03707235Powersupplyunits,24VDC,10A1A5E03707236Distributionboard1A5E03707240FKMhosed=3/5,length=1m25E03707757MEDLUVlampwithheater12A5E03707918Motorflange31A5E03707919Motorflange21A5E03707920Gasfilterwithholder,formeasurementofNO12A5E03707921SIPROCESSUV600chamberH=300mm,aluminum1A5E03707925CalibrationchamberwithholderforNO1A5E03707941CalibrationchamberwithholderforSO2andH2S1A5E03707942CalibrationchamberwithholderforNO21A5E03707943Heaterwith380mmlongcable,forSIPROCESSUV600:MEDL,chamber,motorflange12A5E03707968Moisturesensor12A5E03707969Sparepartsset-pressuresensorwithgasketandO-ring1A5E03707970Flowsensorwithtemperaturesensor12A5E03707971Diaphragmpumptype123,24VDC/50Hz1A5E03707986Diaphragmassembly,EPDMfortypes110-12512A5E03707987O-ringforgaspumpsuspension12A5E03707988ProductdescriptionOrderNo.SIPROCESSUV600gasanalyzer,incl.gasmoduleandbarometricpressurecompensation7MB2621-77777-0777CannotbecombinedSiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/8SiemensPA01NewsFebruary20122■DimensionaldrawingsSIPROCESSUV600,19"rackunit,dimensionsinmmSiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/9SiemensPA01NewsFebruary20122■SchematicsElectricalconnectionsSIPROCESSUV600,gasconnectionsandelectricalconnectionsTheSIPROCESSUV600issuppliedasstandardwithoneor(optionally)twoinput/outputmodules.ThelogicfunctionofthesignalconnectionscanbeconfiguredindividuallywiththeserviceandmaintenancesoftwarespecifictoSIPROCESSUV600.ThesignalconnectionsareavailableatterminalstripsX3,X4,X5andX7onthe12-pinplugconnectorsoftheinput/outputmodules.Thescopeofdeliveryincludesthecorrespondingcounterparts(plugconnectors)withscrewterminals.SIPROCESSUV600,signalconnectionsandplugconnectorsSIEMENSPowerconnectionInterfaces:ARS485/externalinput/outputBRS485/externalinput/outputCReservedforserviceDEthernet(LAN)Signalconnectionsofthesecond,internalinput/outputmodule(optional)Signalconnectionsoftheinternalinput/outputmodule(standard)Internalinput/outputmodule(standard)withterminalstripsX3,X4,X5andX7ConnectionplugSiemensAG2012ContinuousGasAnalyzers,extractiveSIPROCESSUV6002/10SiemensPA01NewsFebruary2012■Schematics(continued)2PinassignmentsSIPROCESSUV600,pinassignmentsofdigitalinputsX3(DI1toDI8)anddigitaloutputsX4(DO1toDO4)andX5(DO5toDO8)Characteristicsofthedigitalinputs:Floatingoptocouplerswithcommonreferencepotential(DIC)Switchingrange14...42VDC(externalcontrolvoltage)ThedigitalinputscanbeoperatedeitherwithpositiveornegativevoltageWithinvertedswitchinglogic,thelogicfunctionofthecontrolinputisactiveifnocurrentisflowingthroughthecontrolinputMaximumvoltage:±50VCharacteristicsofthedigitaloutputs:FloatingrelaychangeovercontactsSingle-polechangeoverswitch,threeconnectionsMaximumvoltage:±50VConnectinductiveloads(e.g.relays,solenoidvalves...)viaspark-quenchingdiodesonlyMaximumload-carryingcapacity(standard):Max.30VAC,max.48VDC,max.500mA.SIPROCESSUV600,pinassignmentoftheanaloginputsX7(AI1andAI2)andanalogoutputsX7(AO1toAO4)Characteristicsoftheanaloginputs:Theinputsignalisananalogcurrentsignal(standard0...20mA,maximum30mA)ThesignalcurrentmustbeprovidedbyanexternalcurrentsourceLoad(internalresistance)ofanaloginput:10ΩReferencepotentialGND(seefigure,analoginputs)Overcurrentprotection:±1000mAMax.voltage:±50VCharacteristicsoftheanalogoutputs:Analogoutputsarefloating(electricallyisolated)andprovideaload-independentcurrentsignalSignalrange0...24mAResidualripple0.02mAResolution0.1%Accuracy0.25%offull-scalevalueMaximumload500ΩMaximumvoltage±50VAdjustablestartorerrorstateNoteforelectricalisolation:TheelectricalisolationiscanceledifthenegativepolesoftheanalogoutputsareconnectedtoGND.
标签: