资料库
仪器网 >
资料库 >O, N determination in titanium samples
O, N determination in titanium samples
本文由 上海科学仪器有限公司 整理汇编
2018-08-16 10:00 2117阅读次数
文档仅可预览首页内容,请下载后查看全文信息!
立即下载
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.
登录或新用户注册
请用手机微信扫描下方二维码 快速登录 或注册新账号
微信扫码,手机电脑联动
更多资料
O, N determination in titanium samples
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
O, N determination in titanium
O, N determination in titanium[详细]
2024-09-28 04:37
产品样册
O, N determination in steel samples
O, N determination in steel samples[详细]
2015-06-24 00:00
操作手册
O, N determination in steel samples
O, N determination in steel samples[详细]
2015-06-24 00:00
期刊论文
O, N determination in steel samples (single graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
O determination in copper samples
O determination in copper samples[详细]
2015-06-24 00:00
操作手册
O, N determination in steel samples (Inner and outer graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
C, S determination in ore samples
C, S determination in ore samples[详细]
2015-06-24 00:00
期刊论文
C, S determination in wood samples
SuitableAnalyzersnCS-580seriesnCS-2000(resistancefurnace)UsedAccessoriesn90160DisposableporcelainboatsnSuitablecalibrationmaterialfromNISTorotherSettingsnFurnaceTemperature:1350°CnComperatorlevel:20nminimumanalysistime:60secondsnmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200m.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof150mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware[详细]
2018-08-16 10:00
产品样册
C, S determination in coal samples
SuitableAnalyzersCS-580seriesCS-2000(resistancefurnace)UsedAccessories90160DisposableporcelainboatsSuitablecalibrationmaterialfromNISTorotherSettingsFurnaceTemperature:1350°CComperatorlevel:20minimumanalysistime:60secondsmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200μm.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof200mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware->Analyzetheunknownsamples.[详细]
2018-08-16 10:00
产品样册
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[详细]
2024-09-18 18:08
课件
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[详细]
2024-09-28 00:08
专利
C, S determination in flue ash samples
C, S determination in flue ash samples[详细]
2015-06-24 00:00
标准
C, S determination in pure iron samples
C, S determination in pure iron samples[详细]
2024-09-18 22:38
专利
皮尔兹PNOZ s5 24VDC 2 n/o 2 n/o t
皮尔兹安全继电器PNOZs524VDC2n/o2n/ot批准:CE,cULus认证,TV,KOSHA,CCC应用选项:安全门监控,瞬时紧急停止监控,限位开关,紧急停止延时监控,光栅设备监控器。4级,光栅设备监控器。2级,非典型,光栅设备监控器。2级,典型值,安全断电延时计时器操作模式:单通道,自动复位,双通道,手动复位,触点间短路检测,启动测试,手动复位监控,不检测触点间短路,自检测,编程延时断电产品标准:EN60947-5-1标准:EN60204-1,EN62061,ENISO13849-1,VDE0113-1供电电压(V):24,0源型:DC终端型:插件皮尔兹安全继电器PNOZs524VDC2n/o2n/ot终端类型:螺丝端子瞬时安全触点数量:2延时安全触点数量:2半导体输出数量:1可选次数:0.04s,0.10s,0.20s,0.30s,0.40s,0.50s,0.60s,0.70s,0.80s,1.00s,1.50s,10.00s,100.00s,12.00s,120.00s,14.00s,140.00s,15.00s,150.00s,16.00s,160.00s,180.00s,2.00s,2.50s,20.00s,200.00s,210.00s,240.00s,25.00s,3.00s,3.50s,30.00s,300.00s,35.00s,4.00s,40.00s,5.00s,50.00s,6.00s,60.00s,7.00s,70.00s,8.00s,80.00s,90.00s停止类别:0/1在DC13处的Zda电流I(6个循环/Z小):4.0A在AC1处的Zda电流5:3.0A宽度尺寸:22.5mm高度尺寸:98.0mm深度尺寸:120.0mm总重:245g净重:235g以摄氏度一表示的环境温度:-10-55°C皮尔兹安全继电器PNOZs524VDC2n/o2n/ot[详细]
2018-10-02 10:01
产品样册
Thermo Scientific™46i-HL型N₂O分析仪
46i-HL型高浓度分析仪使用极ng确的校准曲线,保证了仪器在2,000 ppm的浓度范围内有准确的线性输出,并且可以在双量程和自动量程模式中使用。此外,46i-HL型高浓度分析仪还具有自动压力和温度补偿功能,增强了对冲击和振动的抵抗力,同时提高了产品的特性和灵敏性。[详细]
2020-01-15 15:30
产品样册
Thermo Scientific™ 46i型N₂O分析仪
46i型分析仪使用极ng确的校准曲线,保证了仪器在50ppm的浓度范围内有准确的线性输出,并且可以在双量程和自动范围模式中使用。[详细]
2024-09-29 10:04
产品样册
PILZ继电器PNOZ s3 24VDC 2 n/o
PILZ继电器PNOZs324VDC2n/o技术参数[详细]
2018-11-23 10:00
产品样册
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Traditionally, geological samples are analyzed using flame atomic absorption (FAAS) and/or radial ICP-OES with a vertical torch. Achieving high sample throughput at a low cost per analysis for geochemical samples can be challenging when using these techniques. [详细]
2024-09-29 22:17
标准
皮尔兹PNOZ s4 C 24VDC 3 n/o 1 n/c
皮尔兹安全继电器PNOZs4C24VDC3n/o1n/c产品版本:1.0批准:CE,cULus认证,TV,KOSHA,CCC应用选项:安全门监控,瞬时紧急停止监控,限位开关,光栅设备监控器。4级,光栅设备监控器。2级,非典型,光栅设备监控器。2级,典型值操作模式:单通道,自动复位,双通道,手动复位,触点间短路检测,启动测试,手动复位监控,不检测触点间短路,自检测皮尔兹安全继电器PNOZs4C24VDC3n/o1n/c产品标准:EN60947-5-1标准:EN60204-1,EN62061,ENISO13849-1,VDE0113-1供电电压(V):24,0源型:DC终端型:插件终端类型:弹簧式端子瞬时安全触点数量:3辅助触点数量:1半导体输出数量:1停止类别:0皮尔兹安全继电器PNOZs4C24VDC3n/o1n/c在DC13处的Zda电流I(6个循环/Z小):5.0A在AC1处的Zda电流5:5.0A宽度尺寸:22.5mm高度尺寸:100.0mm深度尺寸:120.0mm总重:200g净重:190g以摄氏度一表示的环境温度:-10-55°C皮尔兹安全继电器PNOZs4C24VDC3n/o1n/c[详细]
2018-10-02 10:01
产品样册
Copyright 2004-2026 yiqi.com All Rights Reserved , 未经书面授权 , 页面内容不得以任何形式进行复制
参与评论
登录后参与评论