资料库
仪器网 >
资料库 >O, N determination in steel samples (single graphite crucibles)
O, N determination in steel samples (single graphite crucibles)
本文由 上海科学仪器有限公司 整理汇编
2018-08-16 10:00 1899阅读次数
文档仅可预览首页内容,请下载后查看全文信息!
立即下载
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.
登录或新用户注册
请用手机微信扫描下方二维码 快速登录 或注册新账号
微信扫码,手机电脑联动
更多资料
O, N determination in steel samples (single graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnGraphitecrucibles(90190)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Placeemptycrucible(90190)ontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
O, N determination in steel samples (Inner and outer graphite crucibles)
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:5mV(lowoxygen);20mV(other)nMinimumtime:15sec(oxygen);35sec(nitrogen)nMaximumtime:3:00minnPostwaiting:20secnBaselinedeviation:20mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:5kWnTimePurge:15secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:40secPower(1):4kWPower(2):4kWSamplepreparationMakesurethatthesurfaceofthesteelisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterial(usuallypins)(3)Placecalibrationmaterialinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
O, N determination in steel samples
O, N determination in steel samples[详细]
2015-06-24 00:00
操作手册
O, N determination in steel samples
O, N determination in steel samples[详细]
2015-06-24 00:00
期刊论文
O, N determination in titanium samples
SuitableanalyzersnON900nONH2000UsedaccessoriesnInnergraphitecrucibles(90180)nOutergraphitecrucibles(90185)nNickelbasket(90250)orAR2344nSuitablecalibrationmaterial(NISTorother)SettingsnComparatorlevel:20mVnMinimumtime:15secnMaximumtime:3:00minnPostwaiting:30secnBaselinedeviation:200mV;Step:16mV;Time:10secnMode:continuousnOutgasTime:45secPower:6kWnTimePurge:20secStability:45secnIntegrationdelayIRcell:2secTCcell:10secnAnalyse(1)Time:75secPower(1):6kWPower(2):6kWSamplepreparationMakesurethatthesurfaceofthetitaniumisfreefromcontaminations;otherwisecleanthesamplewithacetonep.a.andletdryatatmosphere.ProcedurenPrepareELTRAanalyzer(exchangeanhydrone,sodiumhydroxide,copperoxidewhennecessary),cleanfurnace,sampledropmechanism,electrodetipnRunthreeblankswithemptycruciblesnCalibratetheanalyzerwithsuitablecalibrationmaterial(NISTorother)(1)Filloneemptyinnercrucible(90180)inoneoutercrucible(90185)andplacethemontheelectrodetip,closefurnace(F2Button)(2)Weighcalibrationmaterialandgiveitintoanickelbasket(90250orAR2344)(3)Placenickelbasketwithcalibrationmaterialorsampleinthesampledropmechanismandstartanalysis(F5Button)Afteranalysisgivetheinnercrucibleintowasteandfillinanewone.Theoutercruciblescanbeusedapproximately10times.Repeatsteps(1)(3)atleastthreetimes;Marktheresultsandusethecalibrationfunctioninthesoftware.[详细]
2018-08-16 10:00
产品样册
O determination in copper samples
O determination in copper samples[详细]
2015-06-24 00:00
操作手册
O, N determination in titanium
O, N determination in titanium[详细]
2024-09-28 04:37
产品样册
C, S determination in ore samples
C, S determination in ore samples[详细]
2015-06-24 00:00
期刊论文
C, S determination in wood samples
SuitableAnalyzersnCS-580seriesnCS-2000(resistancefurnace)UsedAccessoriesn90160DisposableporcelainboatsnSuitablecalibrationmaterialfromNISTorotherSettingsnFurnaceTemperature:1350°CnComperatorlevel:20nminimumanalysistime:60secondsnmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200m.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof150mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware[详细]
2018-08-16 10:00
产品样册
C, S determination in coal samples
SuitableAnalyzersCS-580seriesCS-2000(resistancefurnace)UsedAccessories90160DisposableporcelainboatsSuitablecalibrationmaterialfromNISTorotherSettingsFurnaceTemperature:1350°CComperatorlevel:20minimumanalysistime:60secondsmaximumanalysistime:180secondsSamplepreparationForbestresultspreparethesampledowntoaparticlesizeabout200μm.Drythesampletillmassconstancyat105°C(inminimumfor1Hour).ProcedurenPrepareandcleantheELTRAanalyzer(f.e.exchangeAnhydron,Sodiumhydroxide)andsetthefurnacetemperatureto1350°CnRuninminimumthreewarmupsamples(f.e.ELTRA92511-3020)withamediumsampleweightof200mguntiltheresultsarestablenCalibratethesystemwithasuitablecalibrationmaterial(fromNISTorother):(1)Weighinasampleweightof200mginthe90160porcelainboots(2)Startanalysis(F5Button)(3)LoadthesampleintothefurnaceandwaituntilthePCcalculatesresultsRepeatStep(1)(3)inminimumforthreetimes;marktheresultsandusethecalibrationfunctioninthesoftware->Analyzetheunknownsamples.[详细]
2018-08-16 10:00
产品样册
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[详细]
2024-09-18 18:08
课件
Determination of agmatine in biological samples by c
Determination of agmatine in biological samples by c[详细]
2024-09-28 00:08
专利
C, S determination in flue ash samples
C, S determination in flue ash samples[详细]
2015-06-24 00:00
标准
C, S determination in pure iron samples
C, S determination in pure iron samples[详细]
2024-09-18 22:38
专利
皮尔兹PNOZ s5 24VDC 2 n/o 2 n/o t
皮尔兹安全继电器PNOZs524VDC2n/o2n/ot批准:CE,cULus认证,TV,KOSHA,CCC应用选项:安全门监控,瞬时紧急停止监控,限位开关,紧急停止延时监控,光栅设备监控器。4级,光栅设备监控器。2级,非典型,光栅设备监控器。2级,典型值,安全断电延时计时器操作模式:单通道,自动复位,双通道,手动复位,触点间短路检测,启动测试,手动复位监控,不检测触点间短路,自检测,编程延时断电产品标准:EN60947-5-1标准:EN60204-1,EN62061,ENISO13849-1,VDE0113-1供电电压(V):24,0源型:DC终端型:插件皮尔兹安全继电器PNOZs524VDC2n/o2n/ot终端类型:螺丝端子瞬时安全触点数量:2延时安全触点数量:2半导体输出数量:1可选次数:0.04s,0.10s,0.20s,0.30s,0.40s,0.50s,0.60s,0.70s,0.80s,1.00s,1.50s,10.00s,100.00s,12.00s,120.00s,14.00s,140.00s,15.00s,150.00s,16.00s,160.00s,180.00s,2.00s,2.50s,20.00s,200.00s,210.00s,240.00s,25.00s,3.00s,3.50s,30.00s,300.00s,35.00s,4.00s,40.00s,5.00s,50.00s,6.00s,60.00s,7.00s,70.00s,8.00s,80.00s,90.00s停止类别:0/1在DC13处的Zda电流I(6个循环/Z小):4.0A在AC1处的Zda电流5:3.0A宽度尺寸:22.5mm高度尺寸:98.0mm深度尺寸:120.0mm总重:245g净重:235g以摄氏度一表示的环境温度:-10-55°C皮尔兹安全继电器PNOZs524VDC2n/o2n/ot[详细]
2018-10-02 10:01
产品样册
Determination of trace elements in steel using the Agilent 7900 ICP-MS
Monitoring and control领 the level of trace element impurities in metals and alloys is important, as impurities can affect the properties of the metal and may degrade the functionality of the finished component.[详细]
2024-09-24 10:13
标准
Thermo Scientific™46i-HL型N₂O分析仪
46i-HL型高浓度分析仪使用极ng确的校准曲线,保证了仪器在2,000 ppm的浓度范围内有准确的线性输出,并且可以在双量程和自动量程模式中使用。此外,46i-HL型高浓度分析仪还具有自动压力和温度补偿功能,增强了对冲击和振动的抵抗力,同时提高了产品的特性和灵敏性。[详细]
2020-01-15 15:30
产品样册
Thermo Scientific™ 46i型N₂O分析仪
46i型分析仪使用极ng确的校准曲线,保证了仪器在50ppm的浓度范围内有准确的线性输出,并且可以在双量程和自动范围模式中使用。[详细]
2024-09-29 10:04
产品样册
PILZ继电器PNOZ s3 24VDC 2 n/o
PILZ继电器PNOZs324VDC2n/o技术参数[详细]
2018-11-23 10:00
产品样册
Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES
Traditionally, geological samples are analyzed using flame atomic absorption (FAAS) and/or radial ICP-OES with a vertical torch. Achieving high sample throughput at a low cost per analysis for geochemical samples can be challenging when using these techniques. [详细]
2024-09-29 22:17
标准
Copyright 2004-2026 yiqi.com All Rights Reserved , 未经书面授权 , 页面内容不得以任何形式进行复制
参与评论
登录后参与评论