BR-UL-WCS Wiring Compartment Securement Tester
Perform standards: UL 1703-2012, IEC 61730-1:2004
Field wiring compartments with covers
Modules designed for the application of a permanently attached wiring system by an installer in the field shall be provided with an enclosed wiring compartment, which provides protection of the conductors and connections from environmental stress, protection from accessibility to live uninsulated parts and strain relief for the attached wiring system.
Wiring Compartment Securement Test
The tensile force required to separate a wiring compartment or box from a module shall not be less than 155.7N or 4 times the wiring compartment or box weight, whichever is greater, when tested as specified in following. For a test in which the superstrate or substrate fails prior to the adhesive, the force required to cause the superstrate or substrate to fail shall be used to determine compliance, and shall not be less than the specified minimum separation force.
Seven assemblies consisting of a wiring compartment or box secured to a module with adhesive as intended are to be tested. One assembly is to be tested in the as-received condition, three after being conditioned in accordance with temperature cyc领 test, section 35, and three after conditioning in accordance with humidity test, section 36.
The force is to be applied to each assembly so as to separate the wiring compartment or box from the module. The force is to be applied until the wiring compartment or box and the module separates; or the superstrate or substrate fails.
报价:¥10000
已咨询1659次光伏组件(UL 1703)测试项目
报价:面议
已咨询66次模拟运输振动台
报价:¥20000
已咨询2627次光伏组件(UL 1703)测试项目
报价:面议
已咨询124次医药包装物理性能测试仪
报价:¥50000
已咨询2362次光伏材料-EVA封装膜测试项目
报价:¥20000
已咨询2070次
报价:¥8000
已咨询2281次
报价:¥30000
已咨询1493次光伏材料-电池片测试项目