氙弧灯耐候试验箱,电池片预衰减试验箱
- 品牌:泊睿
- 型号: BR-PV-Xenon
- 产地:上海
- 供应商报价:面议
-
上海泊睿科学仪器有限公司
-
销售范围售全国
入驻年限第10年
营业执照
- 同类产品光伏材料-电池片测试项目(2件)
立即扫码咨询
联系方式:400-822-6768
联系我们时请说明在仪器网(www.yiqi.com)上看到的!
扫 码 分 享 -
为您推荐
详细介绍
仪器简介:
1) 中/英文软件
2) 加装DayLight滤镜可用于光伏材料光老化试验, 更换AM1.5滤镜后可用于光伏电池预衰减试验.
BR-UL-Xenon Ultraviolet Light Exposure Chamber
Implementation of standards:
① UL 1703-2008 Polymeric materials (quote UL 746C-2006“Ultraviolet Light Exposure”, spectral distribution conform to ASTM G155-2005)
② VDE 0126-5:2008 Junction box “Weather resistance test”, VDE 0126-3:2009 Connector “Weather resistance”,spectral distribution conform to ISO 4892-2-2006
③ ETAG 002-2000, ASTM C1184-2000 Silicone sealant UV age test, spectral distribution conform to ASTM G155-2005
④ General specification of crystalline silicon solar cell for terrestrial application: Cell maximum power in early light attenuation ratio test
Effective area of irradiation: 500×400mm
Measurement point or range:
300~400nm, 290~800nm, 340nm/nm, 420nm/nm
Irradiation uniformity: better than ±10% at 312×312mm
Irradiation deviation: ±2W/m2@300~400nm
Temperature control range: RT~90°C±2.5°C
Air temperature control range: 20~80°C
With refrigeration compressor, spray system
Irradiation, temperature and spray: Program control
Irradiation and temperature closed loop control…
Measurement point or range: 300~400nm, 290~800nm, 340nm/nm, 420nm/nm
Irradiation uniformity: better than ±10% at 312×312mm
Irradiation deviation: ±2W/m2@300~400nm
Temperature control range: RT~90°C±2.5°C
Air temperature control range: 20~80°C
With refrigeration compressor, spray system
Irradiation, temperature and spray: Program control
Irradiation and temperature closed loop control...
① DayLight filter: for junction box and connector test, spectral distribution conform to ASTM G155 and ISO 4892-2 requirements.
② AM1.5 filter (option): for cell maximum power in early light attenuation ratio test, spectral distribution conform to IEC 60904.9 Class C requirements.
Spectral after filter comparison ASTM G155:Wavelengh range Transmission
after filterBenchmark solar ASTM G155 Radiation precent after filter (<290nm) 0.01% 0~0.15% 0~0.15% 0.02% (290~320nm) 2.85% 5.80% 2.6~7.9% 4.34% (320~360nm) 23.90% 40.00% 28.3~40.0% 36.46% (360~400nm) 38.79% 54.20% 54.2~67.5% 59.18% Total UV 65.54% 100.00% 100.00% 100.00%
UL 1703 (UL 746C) test results discriminant:Physical-property consideration Material test method Functional support Tensile strength or Flexural strength (The ultraviolet-exposed side is to be in contact with the two loading points when using the three-point loading method.) Impact resistance Tensile impact, Izod impact, or Charpy impact