SYSTEM
ADR III-7
自动释放率取样系统
研究建立了雷贝拉唑钠肠溶片的往复筒溶出试验方法,确定了关键条件,并用该方法与药典桨法,对比原研制剂和4个仿制制剂的溶出行为。结果显示往复筒法区分力更强,可支持该药品处方工艺优化与仿制药一致性评价,也为类似易降解制剂溶出度研究提供思路。
Part.01
目的:
Objective:
建立雷贝拉唑钠肠溶
片往复筒溶出试验方
法,并考察不同厂家
产品的溶出行为。
Part.02
方法:
Methods:
通过对往复频率、筛网孔径等关键试验条件的筛选考察,建立往复筒试验。温度 37 ℃,往复频率 10 dip · min-1,浸入时间 10 s,滴水时间 20 s,上筛网 20 目,下筛网 40 目,介质分别为 pH 8.0 三羟基甲基氨基甲烷缓冲液、pH 7.4 磷酸盐缓冲液和 pH 6.8 磷酸盐缓冲液,介质体积 250 mL。采用新建立的往复筒溶出条件和《中华人民共和国药典》中规定的桨法溶出条件考察了原研制剂和 4 个仿制制剂的溶出行为,并以相似因子比较溶出行为的相似性。结果:采用桨法条件进行溶出行为评价时,有 2 个仿制制剂与原研制剂的溶出行为相似(f2 > 50),采用往复筒法溶出条件,这 2 个仿制制剂仅 1 个在 pH 8.0 和 pH 7.4 介质条件下的溶出行为相似,其余条件均不相似。
Through the screening and investigation of the key test conditions such as reciprocating frequency and screen aperture, the reciprocating cylinder apparatus test method was established. The temperature was 37 ℃ , the frequency of repetition was 10 dip· min-1 , the immersion time was 10 s, the drip time was 20 s, the upper screen was 20 mesh, the lower screen was 40 mesh, and with 250 mL pH 8.0 tris hydrochloride buffer, pH 7.4 phosphate buffer and pH 6.8 phosphate buffer as the dissolution medium. The dissolution profiles of rabeprazole sodium enteric-coated tables from different pharmaceutical manufacturers were determined by using the newly established reciprocating cylinder method and the dissolution conditions of paddle method specified in Chinese Pharmacopoeia and the dissolution curves of consistency were evaluated by calculating the similarity factor. Results: While using paddle method the dissolution profiles of the two domestic pharmaceutical manufacturers were similar to those of the reference listed drug (f2 > 50). While using reciprocating cylinder method the dissolution profiles of the two domestic pharmaceutical manufacturers were similar only under the conditions of pH 8.0 and pH 7.4, and the other conditions were not similar.
Part.03
结论:
Conclusion:
新建立的往复筒法溶出试验方法具有一定的区分力,可为雷贝拉唑钠肠溶片处方工艺优化和仿制药一致性评价提供支持。本研究亦为其他主药易降解制剂体外溶出度研究提供了思路。
This method can be used to determine the dissolution of rabeprazole sodium enteric-coated tablets with a certain resolution. It can provides assistance for further optimizing manufacturing process and evaluating the consistency of generic drugs. This study also provides an idea for the in vitro dissolution study of other active pharmaceutical ingredients readily degradable preparations.
关键词:往复筒法;体外;溶出行为;相似因子;雷贝拉唑钠;肠溶片;质量评价
Keywords: reciprocating cylinder method; in vitro; drug dissolution; similarity factor; rabeprazole sodium; entericcoated tablets; quality evaluating
Part.04
点击下方链接查看全文:
View the full text:
LOGAN SINCE 1990
客服热线
Tel +400-1003-718全部评论(0条)
LOGAN通用型8位溶出度仪UDT-812A-8
报价:面议 已咨询 4599次
LOGAN通用型溶出度仪UDT-812A-12
报价:面议 已咨询 5077次
LOGAN 8位溶出自动取样系统 SYSTEM 850DL
报价:面议 已咨询 5170次
LOGAN通用型溶出度仪SYSTEM 860DL
报价:面议 已咨询 6814次
LOGAN12位溶出自动取样摄像系统 System 860CDL
报价:面议 已咨询 5413次
LOGAN 释放率测试仪 DISSO III-7
报价:面议 已咨询 4557次
LOGAN 自动释放率取样系统 SYSTEM ADR III-7
报价:面议 已咨询 5531次
LOGAN 全自动流通池法系统 SYSTEM 4000
报价:面议 已咨询 5973次
①本文由仪器网入驻的作者或注册的会员撰写并发布,观点仅代表作者本人,不代表仪器网立场。若内容侵犯到您的合法权益,请及时告诉,我们立即通知作者,并马上删除。
②凡本网注明"来源:仪器网"的所有作品,版权均属于仪器网,转载时须经本网同意,并请注明仪器网(www.yiqi.com)。
③本网转载并注明来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
④若本站内容侵犯到您的合法权益,请及时告诉,我们马上修改或删除。邮箱:hezou_yiqi
参与评论
登录后参与评论